Validation of three viable-cell counting methods: Manual, semi-automated, and automated
نویسندگان
چکیده
A viable cell count is essential to evaluate the kinetics of cell growth. Since the hemocytometer was first used for counting blood cells, several variants of the methodology have been developed towards reducing the time of analysis and improving accuracy through automation of both sample preparation and counting. The successful implementation of automated techniques relies in the adjustment of cell staining, image display parameters and cell morphology to obtain equivalent precision, accuracy and linearity with respect to the hemocytometer. In this study we conducted the validation of three trypan blue exclusion-based methods: manual, semi-automated, and fully automated; which were used for the estimation of density and viability of cells employed for the biosynthesis and bioassays of recombinant proteins. Our results showed that the evaluated attributes remained within the same range for the automated methods with respect to the manual, providing an efficient alternative for analyzing a huge number of samples.
منابع مشابه
مقایسه شمارش خودکار با شمارش دستی نوتروفیلها در تشخیص پریتونیت باکتریال خود به خودی
Introduction: Spontaneous bacterial peritonitis (SBP) is a prevalent complication in the patients with cirrhosis and ascites, which leads to high intrahospital mortality. Diagnosis is made when ascetic fluid neutrophils is ≥250 cells/mm3. Manual counting of neutrophils is time-consuming, technically difficult, expensive and in many cases individual-dependent. In contrast, automated counting ...
متن کاملValidity of Selected WBC Differentiation Flags in Sysmex XT-1800i
Background: Automatic Cell Counter devises make the CBC differential very easy and delivering the results in few second. However, the problem with this device is facing a flag requires a time-consuming microscopic review of the specimen which causes unacceptable wait times for patient as well as costs for laboratories. In this study, we calculated the validity of WBC d...
متن کاملAutomatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images
Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...
متن کاملValidation Study of the Vi-CELLTM XR for Automated Cell Counting of Dendritic Cells
Dendritic cells (DC) population is a key functional constituent of cell based immunotherapy drugs. The correct cell count and adequate viability of DC are one of the quality control criteria for the final product release. Number of viable DC is historically determined by microscopy using manual counting method – Bürker chamber and trypan blue dye for dead cell exclusion. The manual method can h...
متن کاملA Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures
Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...
متن کامل