Retinal oximeter for the blue-green oximetry technique.
نویسندگان
چکیده
Retinal oximetry offers potential for noninvasive assessment of central venous oxyhemoglobin saturation (SO(2)) via the retinal vessels but requires a calibrated accuracy of ±3% saturation in order to be clinically useful. Prior oximeter designs have been hampered by poor saturation calibration accuracy. We demonstrate that the blue-green oximetry (BGO) technique can provide accuracy within ±3% in swine when multiply scattered light from blood within a retinal vessel is isolated. A noninvasive on-axis scanning retinal oximeter (ROx-3) is constructed that generates a multiwavelength image in the range required for BGO. A field stop in the detection pathway is used in conjunction with an anticonfocal bisecting wire to remove specular vessel reflections and isolate multiply backscattered light from the blood column within a retinal vessel. This design is tested on an enucleated swine eye vessel and a retinal vein in a human volunteer with retinal SO(2) measurements of ∼1 and ∼65%, respectively. These saturations, calculated using the calibration line from earlier work, are internally consistent with a standard error of the mean of ±2% SO(2). The absolute measures are well within the expected saturation range for the site (-1 and 63%). This is the first demonstration of noninvasive on-axis BGO retinal oximetry.
منابع مشابه
Reliability of retinal vessel calibre measurements using a retinal oximeter
BACKGROUND Summarised retinal vessel diameters are linked to systemic vascular pathology. Monochromatic images provide best contrast to measure vessel calibres. However, when obtaining images with a dual wavelength oximeter the red-free image can be extracted as the green channel information only which in turn will reduce the number of photographs taken at a given time. This will reduce patient...
متن کاملPulse oximeter changes with sentinel lymph node biopsy in breast cancer.
HYPOTHESIS The changes reported with pulse oximetry after the injection of isosulfan blue for sentinel lymph node identification in patients with breast cancer are consistent and predictable. DESIGN Retrospective study. SETTING University hospital. PATIENTS AND METHODS The complete anesthesia records of 92 patients who underwent sentinel lymph node biopsy with intraparenchymal injection o...
متن کاملAn Attempt on Methemoglobinemia: It’s Treatment and Relationship between Treatment and Cerebral Oximeter Value: Case Presentation
Background: Our paper aimed to investigate whether there was a correlation among the pulse oximetry, cerebral oximetry (CO) and MetHb (methemoglobin) values of a patient with congenital methemoglobinemia who underwent a laparoscopic cholecystectomy operation. Case: The 35year-old male patient with a weight of 70 kg, body massindex (BMI) of 21, American Society of Anesthesia status-2(ASA-2) cate...
متن کاملA Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination
Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...
متن کاملRetinal oximetry measures systemic hypoxia in central nervous system vessels in chronic obstructive pulmonary disease
BACKGROUND Determination of the blood oxyhemoglobin saturation in the retinal vessels of the eye can be achieved through spectrophotometric retinal oximetry which provides access to the state of oxyhemoglobin saturation in the central nervous system circulation. The purpose of this study was to test the capability of the Oxymap T1 oximeter to detect systemic hypoxemia and the effect of suppleme...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 16 10 شماره
صفحات -
تاریخ انتشار 2011