The effect of exposure duration on visual acuity for letter optotypes and gratings

نویسنده

  • J. Jason McAnany
چکیده

This study compared the effects of exposure duration on letter and grating targets in a visual acuity (VA) task and determined if the broadband nature of letters accounts for their temporal summation characteristics. Log MAR (minimum angle of resolution) VA of five individuals (ages 25-36) was measured with a set of tumbling E optotypes for durations of 24 ms to 1s. The Es were either unfiltered or low-pass filtered to determine the object frequencies (cycles per letter; cplE) mediating VA. The retinal frequencies mediating VA for the unfiltered E (cycles per degree; cpdE) were derived from the ratio of cplE to MAR. Values of cpdE were compared to threshold retinal frequency obtained with band-limited Es and gratings to further evaluate the effects of stimulus bandwidth. Both log MAR and log cplE for the unfiltered E decreased as duration increased up to approximately 260 ms, and were constant thereafter. VA also improved for gratings and band-pass filtered Es, but over a shorter time course (approximately 150 ms). The effect of duration on VA for the broadband E, Gabor, and band-pass filtered E was similar when the object frequencies mediating VA were included in the definition of VA by converting to cpdE. The results indicate that the pattern of temporal integration for the tumbling E is related to its broadband nature. Band-pass filtered letters can simplify the interpretation of VA because the object frequency information mediating VA is known exactly and is independent of duration and letter size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Quantitative Investigation on the Effect of Edge Enhancement for Improving Visual Acuity at Different Levels of Contrast

Background: The major limitation in human vision is refractive error. Auxiliary equipment and methods for these people are not always available. In addition, limited range of accommodation in adult people when switching from a far point to a near point is not simply possible. In this paper, we are looking for solutions to use the facilities of digital image processing and displaying to improve ...

متن کامل

Interrelations between measures of visual acuity and parameters of eye movement in congenital nystagmus.

The authors assessed relationships between visual acuity and the amplitude, frequency, intensity, and duration of foveation periods in a retrospective study of 32 patients. Twenty-four patients had congenital idiopathic nystagmus, and eight patients had nystagmus and albinism. Visual acuity was determined for Landolt ring optotypes and, as the extrapolated high-frequency cutoff of the contrast ...

متن کامل

Use of Lea symbols in young children.

ccurate measurement of visual acuity is fundamental to ophthal-mological care for all ages. This measure is used for diagnosis, for documentation of clinical outcomes, for qualification for special education or disability programmes, and for permission to drive a motor vehicle. More than 20 years ago the importance of ensuring that such a measure be scientifically rigorous was recognised with t...

متن کامل

Event-Related Potentials Allow for Optotype-Based Objective Acuity Estimation.

PURPOSE The event-related potential P300 has been proposed for objective acuity estimation. In contrast to the acuity VEP, which relies on grating or checkerboard stimuli, the P300 can be recorded to small stimulus differences, making it suitable to use optotype stimuli. This may result in a better agreement with subjective measures of acuity than that found with VEP-based estimates. We tested ...

متن کامل

Vanishing Optotype acuity: repeatability and effect of the number of alternatives.

PURPOSE Vanishing Optotype letters have a pseudo high-pass design so that the mean luminance of the target is the same as the background and the letters thus 'vanish' soon after the resolution threshold is reached. We wished to determine the variability of acuity measurements using these letters compared to conventional letters, and in particular how acuity is affected by the number of alternat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 105  شماره 

صفحات  -

تاریخ انتشار 2014