Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report

نویسندگان

  • Daisuke Sugiyama
  • Shigeo Ikeno
  • Tetsuya Tsuchihashi
  • Shigeru Yokota
  • Hiroaki Ina
  • Tetsuya Kono
  • Kunihiko Yamashita
  • Mikito Kawamata
چکیده

Pulmonary artery (PA) rupture caused by a PA Swan-Ganz catheter is a rare complication but remains fatal in almost 50% of cases. False aneurysm of the PA is a rare presentation of PA rupture and should be considered as a possible diagnosis in a patient with a new lung mass after PA catheterization. We present a case of sudden-onset pulmonary alveolar hemorrhage during cardiovascular surgery due to a traumatic PA false aneurysm. The Swan-Ganz catheter might have been displaced by the thoracic aortic aneurysm with displacement of the catheter causing the false aneurysm and bleeding.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stenting as a Rescue Treatment of a Pulmonary Artery False Aneurysm Caused by Swan-Ganz Catheterization

Pulmonary vascular injury is a rare but life-threatening complication of Swan-Ganz catheterization. We report an 82-year old patient who underwent right heart catheterization by a balloon-tipped catheter because of suspected pulmonary hypertension. After deflation of the catheter in the wedge position, hemoptoe appeared associated with acute respiratory insufficiency requiring respiratory suppo...

متن کامل

Opacity over the left hemithorax after abdominal aortic aneurysm repair.

A 77-yr-old male was admitted for aortic aneurysm repair. His history recorded hypertension, left carotid artery desobstruction, stroke and an anterior invocardial infarction. Aspirin was discontinued 1 day before surgery. For periand postoperative haemodynamic surveillance, a Swan-Ganz catheter (7.5 Fr thermodilution catheter; Criticath; Ohmeda, Bilthoven, the Netherlands) was introduced throu...

متن کامل

DONNELLY , LEVINSON ANI ) G RRIIFITHH TABLE 1 . - Findings at Cardiac Catheterization Case

Cardiac catheterization and angiocardiography studies are reported in two patients with syphilitic aortic aneurysms, both of which compromised the pulmonary circulation. In the first instance the right main pulmonary artery was compressed and pulmonary hypertension proximal to the compression resulted. In the second patient the aneurysm ruptured into the pulmonary artery producing an aortic-pul...

متن کامل

HUGE ANEURYSM OF T H E DUCTUS ARTERIOSUS IN CHILDHOOD: CASE REPORT AND LITERATURE REVIEW

Patent ductus arteriosus (PDA) is an open communication between the upper descending thoracic aorta and the proximal left pulmonary artery, which results from persistence of the fetal ductus arteriosus. It may be isolated or occur with other congenital cardiac anomalies. Aneurysms of the ductus arteriosus are rare lesions which may occur as a spontaneous. infantile fonn or occur in later c...

متن کامل

Iatrogenic pulmonary artery pseudoaneurysm: images from different modalities.

A 68-year-old woman was referred for investigation of pulmonary artery hypertension. Right heart catheterisation was performed and the tip of the catheter was positioned in the right middle lobe pulmonary artery under fluoroscopic guidance. A Swan–Ganz balloon was inflated to record a pressure of 78/23 mm Hg (mean 42 mm Hg). Immediately after the balloon was inflated, the patient experienced sm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 67  شماره 

صفحات  -

تاریخ انتشار 2014