Report on the evaluation of the VA/Seattle below-knee prosthesis.
نویسندگان
چکیده
The Department of Veterans Affairs (VA), Rehabilitation Research and Development (Rehab R&D) Service, Technology Transfer Section (TTS) with collaboration from the Prosthetic and Sensory Aids Service (PSAS) managed clinical trials to evaluate the VA/Seattle Below-Knee (BK) Prosthetic System. The clinical trials were held at the Prosthetic Treatment Center (PTC), VA Medical Center, Hines, Illinois. Five other VA medical centers participated in the outreach program of the trials as satellite stations, with PTC Hines as the central fabrication facility. The VA/Seattle BK system is the first complete prosthetic system designed and developed by the Department of Veterans Affairs. It consists of a socket designed and fabricated using computer-aided, automated technology, and off-the-shelf modular components: a lightweight pylon and an ankle unit, and a lightweight, energy-storing foot. The computer-based socket design software, the modular components, and the prosthetic foot were developed with funds from the VA Rehab R&D Service. The evaluation trials were conducted to determine the efficacy of the VA/Seattle prosthesis, its reliability, and acceptance by veterans. The clinical trials began in April 1991 and were completed in August 1992. Forty-six BK amputee veterans were fitted with the VA/Seattle prosthesis. Their progress with the prosthesis was followed for a period of 6 months and data were gathered at intervals of 2 weeks, 3 months, and 6 months. Forty sets of subject data instruments were collected. In order to maintain the accuracy of the results, TTS used the 22 sets that were complete for data analysis.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Report on the evaluation of the DAV/Seattle Knee.
The Department of Veterans Affairs (VA) Rehabilitation Research and Development Service, Technology Transfer Section (TTS) managed a clinical evaluation of the DAV/Seattle Knee with collaboration from the Prosthetic and Sensory Aids Service (PSAS), VA Central Office (VACO) at 16 VA Medical Facilities, recruiting 46 subjects. The DAV/Seattle Knee was designed to provide a functional, lightweight...
متن کاملDynamics of a Running Below-Knee Prosthesis Compared to Those of a Normal Subject
The normal human running has been simulated by two-dimensional biped model with 7 segments. Series of normal running experiments were performed and data of ground reaction forces measured by force plate was analyzed and was fitted to some Fourier series. The model is capable to simulate running for different ages and weights at different running speeds. A proportional derivative control algorit...
متن کاملInvestigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach
Introduction: Metal prostheses in patients affect the radiotherapy dose distribution. Metal prostheses with high density and atomic number cause major changes in scattering and attenuation of radiation. The present study aims to assess the impact of metal knee prosthesis with various dimensions and materials on radiotherapy dose distribution. Material and Methods: In this research, the Varian L...
متن کاملDesign and Evaluation of a Magnetorheological Damper Based Prosthetic Knee
In this work, a magnetorheological (MR) damper based above-knee prosthesis is design and evaluated based on its performance in swing phase and in stance phase. Initially, a dynamic system model for swing phase of a prosthetic leg incorporating a single-axis knee with ideal MR damper was built. The dynamic properties of the damper are represented with Bingham parametric model. From Bingham model...
متن کاملEffect on gait using various prosthetic ankle-foot devices.
Five different commonly prescribed ankle-foot devices for below-knee prostheses were tested for effects on gait: SACH, SAFE, SEATTLE, SINGLE AXIS, and MULTIPLE AXIS. Subjective ratings by the amputees served to resolve which physical variables determined the preferred ankle-foot device. Ratings were related to age, body weight, length of residual limb, and ratio of stride frequency to stride le...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 30 2 شماره
صفحات -