Flow injection hydride generation electrothermal atomic absorption spectrometry with in-atomizer trapping for the determination of lead in calcium supplements.

نویسندگان

  • J F Tyson
  • R I Ellis
  • G Carnrick
  • F Fernandez
چکیده

Lead hydride was generated from acid solution, containing potassium ferricyanide as an oxidizing agent, by the reaction with alkaline borohydride solution. The effects of reaction conditions (hydrochloric acid, ferricyanide and borohydride concentrations), and the lengths of reaction and stripping coils were studied. The effects of trapping temperature and argon flow rate were also investigated. Under the conditions giving the best peak area sensitivity, the detection limit (concentration giving a signal equal to three S.D. of the blank signal) was 0.12 mug l(-1) for a 1000 mul injection volume. The detection limit was improved to 0.03 mug l(-1) when the ferricyanide was purified by passage through a cation-exchange resin. Two calcium supplement materials were analyzed by the flow injection (FI)-hydride generation (HG)-electrothermal atomization atomic absorption spectrometry (ETAAS) method, giving values of 0.55 and 0.66 mug g(-1), in agreement with results obtained by previously validated methods. For a 500-mg sample the limits of detection and quantification were 0.006 and 0.02 mug g(-1), respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Cadmium in Environmental Sample by Electrochemical Hydride Generation Electrothermal Atomic Absorption with in Situ Trapping in Graphite Tube Atomizer

A homemade batch electrolytic cell with a Sn-Pb alloy cathode used to generate cadmium hydride. Several parameters influencing the electrochemical hydride generation and trapping on the coated graphite tubes, and atomization process have been investigated. Ir-, W-, and Zrcoated graphite tubes were used for trapping cadmium hydride. It was found that Ir-coated graphite provided the best sensitiv...

متن کامل

On-line Preconcentration of Nickel by Carbonyl Vaporization With Flow Injection and Continuous Flow Systems in Combination With Sensitive Determination by Electrothermal Atomic Absorption Spectrometry

A sensitive method is described for the on-line determination and preconcentration of nickel using the coupling of a flow system (continuous flow and flow injection) with transversely heated electrothermal atomic absorption spectrometry. The method is based on the volatilization of nickel as nickel tetracarbonyl and its trapping on a graphite surface. The carbonyl generation is optimized by usi...

متن کامل

Determination of lead in wine and rum samples by flow injection-hydride generation-atomic absorption spectrometry.

A method for direct determination of lead in wine and rum samples was developed, using a flow injection hydride generation system coupled to an atomic absorption spectrometer with flame-quartz atomizer (FI-HG-AAS). Lead hyride (PbH(4)) was generated using potassium ferricyanide (K(3)Fe(CN)(6)), as oxidant and sodium tetrahydroborate (NaBH(4)) as reductant. Samples were acidified to 0.40% (v/v) ...

متن کامل

Interferences in the quartz tube atomizer during arsenic and antimony determination by hydride generation atomic absorption spectrometry

Interferences of some metals in the determination of arsenic by hydride generation atomic absorption spectrometry utilizing a quartz tube atomizer were studied. The atomizers were coated under vacuum with Ni, Au, Pd and Cr. The arsenic signal was almost totally suppressed by all the metal coatings and thus the interferences from metal ions in the determination of arsenic were attributed both to...

متن کامل

Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop

The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 52 3  شماره 

صفحات  -

تاریخ انتشار 2000