Individually programmable cell stretching microwell arrays actuated by a Braille display.
نویسندگان
چکیده
Cell culture systems are often static and are therefore nonphysiological. In vivo, many cells are exposed to dynamic surroundings that stimulate cellular responses in a process known as mechanotransduction. To recreate this environment, stretchable cell culture substrate systems have been developed, however, these systems are limited by being macroscopic and low throughput. We have developed a device consisting of 24 miniature cell stretching chambers with flexible bottom membranes that are deformed using the computer-controlled, piezoelectrically actuated pins of a Braille display. We have also developed efficient image capture and analysis protocols to quantify morphological responses of the cells to applied strain. Human dermal microvascular endothelial cells (HDMECs) were found to show increasing degrees of alignment and elongation perpendicular to the radial strain in response to cyclic stretch at increasing frequencies of 0.2, 1, and 5 Hz, after 2, 4, and 12h. Mouse myogenic C2C12 cells were also found to align in response to the stretch, while A549 human lung adenocarcinoma epithelial cells did not respond to stretch.
منابع مشابه
Spatial Resolution of Single-Cell Exocytosis by Microwell-Based Individually Addressable Thin Film Ultramicroelectrode Arrays
We report the fabrication and characterization of microwell-based individually addressable microelectrode arrays (MEAs) and their application to spatially and temporally resolved detection of neurotransmitter release across a single pheochromocytoma (PC12) cell. The microwell-based MEAs consist of 16 4-μm-width square ultramicroelectrodes, 25 3-μm-width square ultramicroelectrodes, or 36 2-μm-w...
متن کاملA Simple Method for Fabrication of Microstructures Using a PDMS Stamp
We report a simple method to fabricate PDMS (polydimethylsiloxane) microwell arrays on glass by using a PDMS stamp to study cell-to-cell adhesion. In the cell-to-cell study, a glass substrate is required since glass has better cell attachment. The microwell arrays are replicated from an SU-8 master mold, and then are transferred to a glass substrate by lifting the PDMS stamp, followed by oxygen...
متن کاملControlled-size embryoid body formation in concave microwell arrays.
Embryonic stem (ES) cells hold great potential as a renewable cell source for regenerative medicine and cell-based therapy. Despite the potential of ES cells, conventional stem cell culture methods do not enable the control of the microenvironment. A number of microscale engineering approaches have been recently developed to control the extracellular microenvironment and to direct embryonic ste...
متن کاملShrink-induced single-cell plastic microwell array.
The ability to interrogate and track single cells over time in a high-throughput format would provide critical information for fundamental biological understanding of processes and for various applications, including drug screening and toxicology. We have developed an ultrarapid and simple method to create single-cell wells of controllable diameter and depth with commodity shrink-wrap film and ...
متن کاملA Bidirectional Text Transcription of Braille for Odia, Hindi, Telugu and English via Image Processing on Fpga
Communication gap establishes an aura of unwillingness of understanding the factor behind. Basically, this is one of the common agenda for the visually challenged people. In order to bridge this gap, a proper platform of learning for both the mass and the visually challenged for any native language is emphasized in this paper through Braille pattern. Braille, a code, well known to visually chal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomaterials
دوره 29 17 شماره
صفحات -
تاریخ انتشار 2008