International Society for Analytical Cytology biosafety standard for sorting of unfixed cells.

نویسندگان

  • Ingrid Schmid
  • Claude Lambert
  • David Ambrozak
  • Gerald E Marti
  • Delynn M Moss
  • Stephen P Perfetto
چکیده

BACKGROUND Cell sorting of viable biological specimens has become very prevalent in laboratories involved in basic and clinical research. As these samples can contain infectious agents, precautions to protect instrument operators and the environment from hazards arising from the use of sorters are paramount. To this end the International Society of Analytical Cytology (ISAC) took a lead in establishing biosafety guidelines for sorting of unfixed cells (Schmid et al., Cytometry 1997;28:99-117). During the time period these recommendations have been available, they have become recognized worldwide as the standard practices and safety precautions for laboratories performing viable cell sorting experiments. However, the field of cytometry has progressed since 1997, and the document requires an update. METHODS Initially, suggestions about the document format and content were discussed among members of the ISAC Biosafety Committee and were incorporated into a draft version that was sent to all committee members for review. Comments were collected, carefully considered, and incorporated as appropriate into a draft document that was posted on the ISAC web site to invite comments from the flow cytometry community at large. The revised document was then submitted to ISAC Council for review. Simultaneously, further comments were sought from newly-appointed ISAC Biosafety committee members. RESULTS This safety standard for performing viable cell sorting experiments was recently generated. The document contains background information on the biohazard potential of sorting and the hazard classification of infectious agents as well as recommendations on (1) sample handling, (2) operator training and personal protection, (3) laboratory design, (4) cell sorter set-up, maintenance, and decontamination, and (5) testing the instrument for the efficiency of aerosol containment. CONCLUSIONS This standard constitutes an updated and expanded revision of the 1997 biosafety guideline document. It is intended to provide laboratories involved in cell sorting with safety practices that take into account the enhanced hazard potential of high-speed sorting. Most importantly, it states that droplet-based sorting of infectious or hazardous biological material requires a higher level of containment than the one recommended for the risk group classification of the pathogen. The document also provides information on safety features of novel instrumentation, new options for personal protective equipment, and recently developed methods for testing the efficiency of aerosol containment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

International Society for the Advancement of Cytometry cell sorter biosafety standards.

Flow cytometric cell sorting of biological specimens has become prevalent in basic and clinical research laboratories. These specimens may contain known or unknown infectious agents, necessitating precautions to protect instrument operators and the environment from biohazards arising from the use of sorters. To this end the International Society of Analytical Cytology (ISAC) was proactive in es...

متن کامل

Standard safety practices for sorting of unfixed cells.

Cell sorting of viable biological specimens has become widespread in laboratories involved in basic and clinical research. As these samples can contain infectious agents, precautions to protect instrument operators and the environment from hazards arising from the use of sorters are paramount. This unit presents a revised and updated version of the biosafety guidelines for sorting of unfixed ce...

متن کامل

Introduction to the biosafety guidelines for sorting of unfixed cells.

Cell sor ting of biologic specimens by flow cytometry has become a widely used technique in r esear ch and clinical laborator ies. Because viable biologic specimens can contain infectious agents, pr ecautions need to be taken to prevent the exposure of operators of flow cytometers to biohazards ar ising from the use of these instruments. The International Society of Analytical Cytology (ISAC) r...

متن کامل

Ultra high-speed sorting.

BACKGROUND Cell sorting has a history dating back approximately 40 years. The main limitation has been that, although flow cytometry is a science, cell sorting has been an art during most of this time. Recent advances in assisting technologies have helped to decrease the amount of expertise necessary to perform sorting. METHODS Droplet-based sorting is based on a controlled disturbance of a j...

متن کامل

Flow sorting from organ material by intracellular markers.

BACKGROUND Fluorescence-activated cell sorting (FACS) is an attractive technique for gene or protein expression studies in rare cell populations. For cell types where specific surface markers are not known, intracellular markers can be used. However, this approach is currently held to be difficult, as the required fixation and permeabilization may cause protein modification and RNA degradation....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cytometry. Part A : the journal of the International Society for Analytical Cytology

دوره 71 6  شماره 

صفحات  -

تاریخ انتشار 2007