Spin exchange broadening of magnetic resonance lines in a high-sensitivity rotating K-Rb-21Ne co-magnetometer
نویسندگان
چکیده
Atomic co-magnetometers can be utilized for high-precision angular velocity sensing or fundamental physics tests. The sensitivity of a co-magnetometer determines the angle random walk of an angular velocity sensor and the detection limit for a fundamental physics test. A high-sensitivity K-Rb-21Ne co-magnetometer, which is utilized for angular velocity sensing, is presented in this paper. A new type of spin relaxation of Rb atom spins, which can broaden the zero-field magnetic resonance lines of the co-magnetometer, is discovered. Further studies show that the spin relaxation of Rb atoms is caused by a high Rb electron magnetization field. With this discovery, the total relaxation rate of Rb atoms is optimized to improve the sensitivity of the co-magnetometer. Moreover, its sensitivity is optimized by suppressing various noises. Especially, to suppress laser-related noises, the co-magnetometer is designed such that the sensitive axis of the co-magnetometer can be fixed to the direction in which the projection input of the earth's rotation is 0. This is called a rotating co-magnetometer. A magnetic field sensitivity of 1.0 fT/Hz-1/2@5 Hz, which is equal to an angular velocity sensitivity of 2.1 × 10-8 rad s-1 Hz-1/2@5 Hz, is demonstrated using a spherical vapour cell with a diameter of 14 mm.
منابع مشابه
Spin Exchange Optical Pumping of Neon and Its Applications
Hyperpolarized noble gases are used in a variety of applications including medical diagnostic lung imaging, tests of fundamental symmetries, spin filters, atomic gyroscopes, and atomic magnetometers. Typically 3He is utilized because large 3He polarizations on the order of 80% can be achieved. This is accomplished by optically pumping an alkali vapour which polarizes a noble gas nucleus via spi...
متن کاملEffects of diffusion and surface interactions on the line shape of electron paramagnetic resonances in the presence of a magnetic field gradient
In an evanescent wave magnetometer the Zeeman polarization is probed at micrometer to submicrometer distances from the cell surface. The electron paramagnetic resonance lines of an evanescent wave magnetometer in the presence of a magnetic field gradient exhibit edge enhancement seen previously in nuclear magnetic resonance lines. We present a theoretical model that describes quantitatively the...
متن کاملNonperturbative broadening of paramagnetic resonance lines by transverse magnetic field gradients
We experimentally and theoretically study the broadening of paramagnetic resonance lines by transverse magnetic field gradients when a perturbative description is inadequate. The experiments are performed with an evanescent wave magnetometer using an octadecyltrichlorosilane-coated glass cell containing Rb and N2 buffer gas. We find that the transverse broadening of the resonance line is invers...
متن کاملMeasurement of spin-exchange and relaxation parameters for polarizing 21Ne with K and Rb
Hyperpolarized K-3He comagnetometers have been used for tests of fundamental physics and inertial rotation sensing. These experiments will demonstrate increased sensitivity if the 3He buffer gas is replaced with 21Ne. We measure the parameters necessary to realize implementation of an alkali-metal–21Ne comagnetometer for two promising alkali-metal species, Rb and K. The spin-exchange rate const...
متن کاملHigh-sensitivity atomic magnetometer unaffected by spin-exchange relaxation.
Alkali-metal magnetometers compete with SQUID detectors as the most sensitive magnetic field sensors. Their sensitivity is limited by relaxation due to spin-exchange collisions. We demonstrate a K magnetometer in which spin-exchange relaxation is completely eliminated by operating at high K density and low magnetic field. Direct measurements of the signal-to-noise ratio give a magnetometer sens...
متن کامل