Parametric modulation of an atomic magnetometer.

نویسندگان

  • Zhimin Li
  • Ronald T Wakai
  • Thad G Walker
چکیده

The authors report on a rubidium atomic magnetometer designed for use in a shielded environment. Operating in the spin-exchange relaxation-free regime, the magnetometer utilizes parametric modulation of the z-magnetic field to suppress noise associated with airflow through the oven and to simultaneously detect x- and y-field components, using a single probe beam, with minimal loss of sensitivity and bandwidth. A white noise level of 60 fT/(Hz)(1/2) was achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A sensitive and accurate atomic magnetometer based on free spin precession

We present a laser-based atomic magnetometer that allows inferring the modulus of a magnetic field from the free Larmor precession of spin-oriented Cs vapour atoms. The detection of free spin precession (FSP) is not subject to systematic readout errors that occur in phase feedback-controlled magnetometers in which the spin precession is actively driven by an oscillating field or a modulation of...

متن کامل

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in Rb has been constructed and tested towards a goal of airborne detection of 87 magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidi...

متن کامل

MPS and ACS with an atomic magnetometer

We show that a single atomic magnetometer in a magnetically unshielded environment can be used to perform magnetic particle spectroscopy (MPS) and AC susceptometry (ACS) on liquid-suspended magnetic nanoparticles. We demonstrate methods allowing a simultaneous recording of M (H ) and dM /dH (H ) dependences of samples containing down to 1 μg of iron. Our results pave the way towards an atomic m...

متن کامل

NMR detection with an atomic magnetometer.

We demonstrate detection of NMR signals using a noncryogenic atomic magnetometer and describe several novel applications of this technique. A nuclear spin-precession signal from water is detected using a spin-exchange-relaxation-free potassium magnetometer. We also demonstrate detection of less than 10(13) 129Xe atoms whose NMR signal is enhanced by a factor of 540 due to Fermi-contact interact...

متن کامل

Investigation of Scalar Modulation Instability in the Presence of Raman Scattering in Photonic Crystal Fibers

In this paper, by including Raman scattering in the coupled-mode equations, the scalar modulation instability in photonic crystal fibers is investigated. The evolution of the pump, Stokes and anti-Stokes waves along the fiber as well as the conversion efficiency for two cases, with and without Raman effect, are studied. The effect of anti-Stokes seed and the pump depletion on the evolution of S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied physics letters

دوره 89 13  شماره 

صفحات  -

تاریخ انتشار 2006