Methodology for Deriving Clear-Sky Erythemal Calibration Factors for UV Broadband Radiometers of the U.S. Central UV Calibration Facility

نویسندگان

  • KATHLEEN O. LANTZ
  • PATRICK DISTERHOFT
  • JOHN J. DELUISI
  • AMBLER THOMPSON
  • JAMES SLUSSER
چکیده

In the United States, there are several federal agencies interested in the effects of UV radiation, which has resulted in the establishment of UV monitoring programs each with their own instrumentation and sites designed to address their specific needs. In 1993, participating agencies of the U.S. Global Change Research Program organized a UV Panel for coordinating the different agencies’ programs in order to ensure that UV data are intercalibrated, have common quality assurance and control procedures, and that the efforts among agencies are not duplicated. In order to achieve these goals, in 1994 the UV Panel recommended formation of the U.S. Central UV Calibration Facility (CUCF), which is operated by the Surface Radiation and Research Branch of the Air Resources Laboratory of National and Oceanic Atmospheric Administration. The CUCF is responsible for characterizing and calibrating UV measuring instruments from several U.S. federal agencies. Part of this effort is to calibrate UVB broadband radiometers from these agencies. The CUCF has three Yankee Environmental Systems (YES UVB-1) and three Solar Light (SL 501A) broadband radiometers as reference standards that are routinely calibrated. For the past three years, clear-sky erythema calibration factors were determined for these standard UVB broadband radiometers by using simultaneously measured erythema-weighted irradiance determined during the annual North American Intercomparison. Comparisons between erythemally weighted irradiance calculated spectra supplied by spectroradiometers typically agreed better than 62% for solar zenith angles less than 608. The spectroradiometers were participating in an intercomparison event organized by the National Institute of Standards and Technology and the CUCF. In this article, the calibration methodology is described for transferring the calibration from the spectroradiometers to the CUCF’s standard broadband radiometers. The CUCF standard broadband radiometers are used to calibrate UVB broadband radiometers from several U.S. UV monitoring networks. Erythemal calibration factors for the CUCF’s YES UVB-1 standard broadband radiometer triad are reported for 1994, 1995, and 1996. Erythemal calibration factors for CUCF’s SL 501A standard broadband radiometer triad are reported for 1996.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intercomparison of erythemal broadband radiometers calibrated by seven UV calibration facilities in Europe and the USA

1 Physikalisch-Meteorologisches Observatorium Davos / World Radiation Center, Dorfstrasse 30, 7278 Davos Dorf, Switzerland 2 Aristotle University of Thessaloniki, Laboratory of Atmospheric Physics, Campus Box 149, 541 24 Thessaloniki, Greece 3 Innsbruck Medical University, Division for Biomedical Physics, Müllerstr. 44, 6020 Innsbruck, Austria 4 National Oceanic and Atmospheric Administration, ...

متن کامل

Development and evaluation of an extensive calibration procedure for UV filter radiometers

As a consequence of stratospheric ozone depletion and due to the current uncertainties in the Earth’s climate, ultraviolet radiation observations are becoming increasingly important and nowadays form a part of many radiation monitoring networks. UV irradiance is commonly measured either with spectrophotometers or with filter instruments. While the most accurate UV radiation measurements are obt...

متن کامل

Solar ultraviolet-B radiation in urban environments: the case of Baltimore, Maryland.

Ultraviolet-B radiation (UV-B, 280-320 nm) has important effects in urban areas, including those on human health. Broadband UV-B radiation is monitored in Baltimore, MD, as part of the Baltimore Ecosystem Study, a long-term ecological research program. We compare broadband UV-B irradiance in Baltimore with UV-B at two nearby locations: a more rural station 64 km southeast and a suburban station...

متن کامل

7.4 European Uv Broad Band Filter Radiometer Reference Scale

The pertinent lack of a standard calibration procedure for UV filter radiometers introduces unknown and potentially large uncertainties in their measurement products. Although most UV calibration facilities take into account many instrument properties that affect the measurement quality of UV filter radiometers, some instrument characteristics that are difficult to determine present substantial...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999