Effect of pre-heating resin composite on restoration microleakage.

نویسندگان

  • Warren C Wagner
  • Mert N Aksu
  • Ann-Marie L Neme
  • Jackson B Linger
  • Frank E Pink
  • Stephen Walker
چکیده

Improving the adaptation of resin composites during placement is necessary to increase durability and reduce microleakage. Flowable resin liners have been introduced to improve adaptation in composite restorations. In addition, a device that lowers the viscosity of regular dental composites has been introduced (Calset, AdDent Inc, Danbury, CT, USA). This device lowers the viscosity of composites by preheating them to 54.4 degrees C, which should lead to improved adaptation. This study compared microleakage in Class II composite restorations prepared using: 1) preheated resin composite, 2) unheated composite and 3) a flowable liner followed by unheated composite. Class II cavities were prepared on the mesial and distal surfaces of extracted third molars. Ten preparations were restored with resin composite (Esthet-X, Dentsply, York, PA, USA) for each of the following four techniques: Control (Esthet-X with Prime & Bond NT, Dentsply), Flowable (f) (as Control but used Esthet-X Flow liner), Preheated (p) (as Control but with preheating composite to 54.4 degrees C) and Delay (d) (as Preheated but followed by a 15-second delay before curing). The teeth were restored, finished, stored in distilled water for 24 hours, then thermocycled between water bath temperatures of 5 degrees C and 55 degrees C with a one-minute dwell time for 1000 cycles. Tooth apices were sealed with epoxy and varnish was applied to within 1 mm of the restoration margins. The teeth were placed in 0.5% basic fuschin dye for 24 hours, rinsed, then embedded in self-curing resin. The embedded teeth were sectioned mesiodistally with a slow-speed diamond saw, providing multiple sections per restoration. Microleakage was rated by two evaluators using a 0-4 ordinal scale at the occlusal and cervical margins of each restoration and light microscopy (40x). The data were analyzed with Kruskal-Wallis ANOVA and pairwise testing with the Sign test (alpha=0.05). No statistical differences were observed among materials at the occlusal margin. However, at the cervical margin, the preheated samples P showed statistically lower microleakage than the controls and all other treatments. The D samples showed higher microleakage than the P and F samples. Ranked sum scores for the cervical were D (4516), C (3974), F (2756) and P (1958). There was a statistically greater amount of leakage at the cervical margins compared to the occlusal p<0.05. Preheating the composite resulted in significantly less microleakage at the cervical margins compared to the flowable liner and control. Delaying light curing of the preheated composite for 15 seconds (D) was counterproductive and led to increased microleakage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of a Glass Ceramic Insert in Sandwich Technique on Microleakage in Class II Composite Resin Restorations

Introduction: The aim of the present study was to evaluate the effect of glass ceramic insert in the sandwich technique to reduce microleakage in class II composite resin restorations. Methods: Sixty sound human upper second premolars were selected and randomly divided into six groups (n=10). Class II box-only cavities were prepared in distal aspects of each tooth with gingival margin located a...

متن کامل

Effect of Different Base Materials and Techniques on Microleakage in Class II Composite Open Sandwich Restorations

Aims: This study was performed to compare microleakage in class II composite restorations with flowable composites and dual cure composite resin as intermediate material and also to evaluate the effect of delayed light polymerization of dual cure composite base on microleakage. Materials and methods: Class II box cavities were made with air water spray and divided into four groups. Group 1 was ...

متن کامل

Effect of Chlorhexidine and Ethanol on Microleakage of Composite Resin Restoration to Dentine.

OBJECTIVE To evaluate the effect of chlorhexidine and ethanol on microleakage of composite resin restoration to dentine. METHODS Class II cavities with dentinal margin were prepared on 96 premolar teeth. All specimens were acid-etched, rinsed and dried. Then the samples were randomly divided into four groups according to pre-treatment of the dentine: no treatment (control group); treatment wi...

متن کامل

‌Comparison of microleakage in different methods of restoration ‌in posterior Clv cavities

  ‌Comparison of microleakage in different methods of restoration ‌in posterior Clv cavities     - Dr. N. Mohammadi* Dr. R. Khezrian**   *- Assistant professor of Operative Dentistry Dept. Faculty of Dentistry Tabriz University of Medical Sciences.   ** - Dentist.     Background and aim: Despite improvements in the properties of composites, glass ionomers and other tooth colored materials, a nu...

متن کامل

Microleakage of cervical cavities prepared by an Er:YAG laser or a high-speed handpiece, after restoration using resin composite

Objectives: The purpose of this in vitro study was to evaluate the microleakage of cervical cavities prepared by Er:YAG laser or high-speed hand piece and bur. Methods: This in vitro experimental study was performed on 40 sound permanent third molar teeth randomly assigned into two equal groups (n=20). In the first group, high-speed hand piece and bur and in the second group Er:YAG la...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Operative dentistry

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 2008