A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants.
نویسندگان
چکیده
PURPOSE This study evaluated the stability of implants in 51 patients following a clinical protocol of immediate functional loading. The stability during the first 3 months following implant placement was assessed according to bone type, implant location, and patient gender. MATERIALS AND METHODS Twenty-two male and 29 female patients were treated with 344 Brånemark System implants placed in edentulous bone or extraction sites and put into functional loading using the Teeth in a Day protocol. Each implant was tested for primary stability with resonance frequency analysis (RFA) at the time of implant placement, and RFA was performed at examinations 30, 60, and 90 days following surgery. RESULTS The analysis was based on the 276 implants that were successfully measured using RFA at all postoperative intervals. The clinical implant survival rate was 98.5% for the total population. RFA showed a decrease in bone-implant stability in the first month after implant placement from 70.35 +/- 0.5 to 66.38 +/- 0.50, followed by increases in stability in the second and third months (68.01 +/- 0.50 and 68.82 +/- 0.49, respectively), suggesting a process of adaptive bone remodeling around the implant. In general, lower initial stabilities were seen in softer bone types, in the posterior portions of the jaw compared to anterior areas, and in the female population. DISCUSSION AND CONCLUSION The results of this study suggest an immediate loading protocol should have an undisturbed period of healing for the first 2 months following implant placement. The determination of "predictor" stability levels for different clinical conditions were based on multiple splinted implants, allowing a larger surface area to withstand the distribution of the load. The most significant "predictor" values from a surgical and prosthodontic perspective are those determined in soft bone, in reduced bone, or in areas where lever arms are created as a result of long spans between the implants.
منابع مشابه
Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis
Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...
متن کاملAssessment of implant stability during various stages of healing placed immediately following extraction in an overdenture situation
To assess the implant stability during different stages of healing in an immediate loaded implant soon after extraction. A 73-year-old female came with a chief complaint of bad smell and irritation in her lower front gum region. On examination, she was found to be completely edentulous in the maxillary arch and partially edentulous in the mandibular arch with only the canines present bilaterall...
متن کاملQuintessence Journals
Purpose: To evaluate the efficacy of immediate loading versus early loading at 6 weeks of bar-retained mandibular overdentures supported by two implants placed with a flapless technique. Materials and methods: Sixty patients were randomised: 30 to the immediately loaded group and 30 to the early loaded group. To be immediately loaded, implants had to be inserted with a minimum torque > 48 Ncm. ...
متن کاملProgressive immediate loading of a perforated maxillary sinus dental implant: a case report
The displacement of a dental implant into the maxillary sinus may lead to implant failure due to exposure of the apical third or the tip of the implant beyond the bone, resulting in soft tissue growth. This case report discusses dental implant placement in the upper first molar area with maxillary sinus involvement of approximately 2 mm. A new technique for progressive implant loading was used,...
متن کاملA Simple Technique to Rehabilitate Edentulous Patient with mandibular Overdenture Retained by two Single Piece Bicortical Implants Using Flapless Technique; A Case Report
In completely edentulous patients it is comparatively easy to get retention in maxillary denture due to large surface area than mandibular denture.So conventional complete dentures usually fail to satisfy the expectation of patients because of compromised retention, especiallywith mandibulardentures. This createsnegative effects on thepatient’sbehavior towards prosthodontics treatment. So a reh...
متن کاملThe immediately loaded single implant-retained mandibular overdenture: a 36-month prospective study.
PURPOSE The aim of this study was to ascertain whether simplifying mandibular overdenture treatment by using single-stage surgery and immediate prosthetic loading of a single implant will achieve acceptable implant success rates, functional improvement, and increased patient satisfaction. As part of this study, the Mk III Branemark implant with an oxidized surface was compared to the classic ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 20 4 شماره
صفحات -
تاریخ انتشار 2005