Early fracture of the modular neck of a MODULUS femoral stem
نویسندگان
چکیده
We present the case of a 46-year-old woman who underwent revision surgery approximately 4 years after total hip arthroplasty because of a fracture of the modular neck of a MODULUS femoral stem. The fractured surfaces of the retrieved implant were inspected using optical and scanning electron microscopy. Three-dimensional finite element analysis was also performed to identify the stresses that might have caused the failure. We concluded that active, obese patients who are implanted with a high-offset, small-sized modular component could experience stress-induced fractures of the modular neck, with proper fixation and osseointegration of the distal stem, especially if residual bone or tissue is present on the inner surface of the neck that could contribute to micromovement and decreased proximal fixation.
منابع مشابه
Comment on: Modular titanium alloy neck failure in total hip replacement
To the Editor of the SICOT-J Orthopaedic Journal, I am writing to you as I would like to kindly express some considerations on the case-report of Dr. Marco Ceretti on ‘‘Modular titanium alloy neck failure in total hip replacement’’ published in your on-line journal last April (M. Ceretti and F. Falez SICOT J 2016, 2, 20). The Authors report on ‘‘a case of a repetitive modular femoral neck prost...
متن کاملFemoral prosthesis neck fracture following total hip arthroplasty: a case report.
Fracture of the femoral prosthesis neck following total hip arthroplasty is not common. We report a case of femoral prosthesis neck fracture in an adult male patient following modular, uncemented total hip arthroplasty. This case report further emphasizes the importance of the potentially high loading situation in the prosthetic femoral neck. On the other hand, the occurrence of a femoral prost...
متن کاملEffect of Femoral Stem Modular Neck’s Material on Metal Ion Release
Background In recent decades, the popularity of modular necks in total hip arthroplasty (THA) has increased since modular necks offer the potential to restore the patient's native anatomy, and thus improve stability. Unfortunately, modular necks are associated with higher complication rates, including implant fracture and modular junction corrosion with adverse local tissue reaction to metal de...
متن کاملIntrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture
During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...
متن کاملAn Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur
INTRODUCTION Perioperative complications are well known during partial and total hip arthroplasty. One of the common categories of these complications is an intraoperative fractures of the proximal femur. Here we discuss a case of perforation of posteromedial cortex of the proximal femur, while doing a press fit modular bipolar hemiarthroplasty, in a young adult with secondary nonunion of the f...