Daylight Design of Office Buildings: Optimisation of External Solar Shadings by Using Combined Simulation Methods

نویسنده

  • Javier González
چکیده

Integrating daylight and energy performance with optimization into the design process has always been a challenge for designers. Most of the building environmental performance simulation tools require a considerable amount of time and iterations for achieving accurate results. Moreover the combination of daylight and energy performances has always been an issue, as different software packages are needed to perform detailed calculations. A simplified method to overcome both issues using recent advances in software integration is explored here. As a case study; the optimization of external shadings in a typical office space in Australia is presented. Results are compared against common solutions adopted as industry standard practices. Visual comfort and energy efficiency are analysed in an integrated approach. The DIVA (Design, Iterate, Validate and Adapt) plug-in for Rhinoceros/Grasshopper software is used as the main tool, given its ability to effectively calculate daylight metrics (using the Radiance/Daysim engine) and energy consumption (using the EnergyPlus engine). The optimization process is carried out parametrically controlling the shadings’ geometries. Genetic Algorithms (GA) embedded in the evolutionary solver Galapagos are adopted in order to achieve close to optimum results by controlling iteration parameters. The optimized result, in comparison with conventional design techniques, reveals significant enhancement of comfort levels and energy efficiency. Benefits and drawbacks of the proposed strategy are then discussed. OPEN ACCESS Buildings 2015, 5 561

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the relationship between depth of overhang and amount of daylight indicators in office buildings of Kerman city

Background: The use of daylight in offices has become an effective strategy to improve the quality of indoor space and energy efficiency. There is enough potential to have daylight autonomy in Kerman as a city with more than 300 sunny days a year. Therefore, this study aimed to investigate the relationship between facades configuration and the amount of daylight in office buildings of Kerman. ...

متن کامل

Energy consumption of atria; the case of a commercial-office center in the semi-arid climate of Tehran

According to the energy crisis in the world, optimization of energy consumption is indispensable. Technological advances in constructions and application of renewable energy resources demand saving energy. Atrium, as one of the construction elements, catches sufficient daylight and acts as a passive solar element and results in a decline of energy consumption. This research seeks to evalu...

متن کامل

Energy Conservation using Daylight Energy Transfer through Windows : Case of Office Buildings

The exterior envelope of buildings play a significant role on the amount of energy consumption in office buildings that are located in warm climates. The present study focuses on the reduction of energy consumption by integrating daylight and artificial lights, and by changing the characteristics of exterior envelope of buildings including window coverage and dimension of buildings. Moreover, t...

متن کامل

Design considerations for architectural glazing, with focus on public buildings’ energy demand under Hungarian and similar climate

The aim of this paper is to introduce guidelines as aid for early stage architectural design of public and office buildings with large glazed surfaces in connection with the impact of some solutions on energy demand of the building. Relation between key parameters of architectural glazing (thermal transmission, solar heat gain coefficient and light transmission) has been analysed first using pr...

متن کامل

Effects of Fixed and Motorized Window Louvers on the Daylighting and Thermal Performance of Open-Plan Office Buildings

This study investigates the daylighting and thermal performance of open-plan office buildings with two scenarios of daylight louvers – fixed and motorized ones. Both types are for facade window applications. They redirect transmitted daylight to eliminate glare on occupants and increase daylight levels deeper in the interior space, but have significantly different daylight transmitting characte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015