Comparison of Newer IOL Power Calculation Methods for Eyes With Previous Radial Keratotomy

نویسندگان

  • Jack X. Ma
  • Maolong Tang
  • Li Wang
  • Mitchell P. Weikert
  • David Huang
  • Douglas D. Koch
چکیده

PURPOSE To evaluate the accuracy of the optical coherence tomography-based (OCT formula) and Barrett True K (True K) intraocular lens (IOL) calculation formulas in eyes with previous radial keratotomy (RK). METHODS In 95 eyes of 65 patients, using the actual refraction following cataract surgery as target refraction, the predicted IOL power for each method was calculated. The IOL prediction error (PE) was obtained by subtracting the predicted IOL power from the implanted IOL power. The arithmetic IOL PE and median refractive PE were calculated and compared. RESULTS All formulas except the True K produced hyperopic IOL PEs at 1 month, which decreased at ≥4 months (all P < 0.05). For the double-K Holladay 1, OCT formula, True K, and average of these three formulas (Average), the median absolute refractive PEs were, respectively, 0.78 diopters (D), 0.74 D, 0.60 D, and 0.59 D at 1 month; 0.69 D, 0.77 D, 0.77 D, and 0.61 D at 2 to 3 months; and 0.34 D, 0.65 D, 0.69 D, and 0.46 D at ≥4 months. The Average produced significantly smaller refractive PE than did the double-K Holladay 1 at 1 month (P < 0.05). There were no significant differences in refractive PEs among formulas at 4 months. CONCLUSIONS The OCT formula and True K were comparable to the double-K Holladay 1 method on the ASCRS (American Society of Cataract and Refractive Surgery) calculator. The Average IOL power on the ASCRS calculator may be considered when selecting the IOL power. Further improvements in the accuracy of IOL power calculation in RK eyes are desirable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the American Society of Cataract and Refractive Surgery intraocular lens calculator for eyes with prior radial keratotomy

BACKGROUND The purpose of this study was to evaluate the American Society of Cataract and Refractive Surgery (ASCRS) intraocular lens (IOL) calculator for eyes with prior radial keratotomy and assess the accuracy of its methods in predicting IOL power in patients with previous radial keratotomy. METHODS This retrospective study included data from 15 eyes with previous radial keratotomy and su...

متن کامل

Limitations of Intraoperative Aphakic Refraction Technique for Intraocular Lens Power Calculation

Intraocular lens (IOL) power calculations are known to be difficult in eyes that have had corneal refractive surgery and several methods have been proposed to estimate IOL power. Among the methods not requiring preoperative data, the apahakic refraction technique has been successfully used to calculate IOL power in post-refractive cases and other conditions that cause unreliability in standard ...

متن کامل

Calculation of intraocular lens power using Orbscan II quantitative area topography after corneal refractive surgery.

PURPOSE To present the prospective application of the Orbscan II central 2-mm total-mean corneal power obtained by quantitative area topography in intraocular lens (IOL) calculation after refractive surgery. METHODS Calculated and achieved refraction and the difference between them were studied in 77 eyes of 61 patients with previous radial keratotomy (RK), RK and additional surgeries, myopic...

متن کامل

Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery.

PURPOSE To determine the accuracy of Pentacam Scheimpflug system Holladay equivalent keratometry (K) readings (EKRs) in calculating intraocular lens (IOL) power after corneal refractive surgery, including laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and radial keratotomy (RK). SETTING Jules Stein Eye Institute, David Geffen School of Medicine at University of Calif...

متن کامل

The adjustable refractive surgery concept (ARS)

The primary goal of refractive surgery is the smallest residual refractive error and preserved contrast sensitivity with the same visual capacity under bright and dim illumination. Corneal refractive surgery cannot correct very high ametopias; from -10 to -14 D is the limit of myopia correction in the cornea and from +4 to +6 D, the limit of hyperopia correction. Intraocular refractive surgery ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 57  شماره 

صفحات  -

تاریخ انتشار 2016