Mini-scleral Contact Lens for Management of Poor Visual Outcomes after Intrastromal Corneal Ring Segments Implantation in Keratoconus

نویسندگان

  • Fatemeh Alipour
  • Firoozeh Rahimi
  • Mohammad Naser Hashemian
  • Zahra Ajdarkosh
  • Ramak Roohipoor
  • Masoumeh Mohebi
چکیده

PURPOSE To evaluate the feasibility and efficacy of mini-scleral design (MSD) contact lenses to treat keratoconus patients who were unsatisfied with the results of corneal inlay. METHODS In this prospective interventional case series, 9 eyes of 6 keratoconus patients who were unsatisfied with the results of corneal inlay were fitted with MSD contact lenses. Demographic data, uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and higher order aberrations (HOAs) were evaluated before contact lens fitting. Corrected visual acuity by placing the MSD contact lens with or without over-refraction, and HOAs were measured one hour after contact lens fitting. One month after contact lens wearing, corrected visual acuity by placing the MSD contact lens with over-refraction and possible contact lens related problems were assessed. Ocular comfort and contact lens handling problems were asked in follow-up visits. The data was analyzed using descriptive statistical tests. RESULTS Nine eyes of 6 patients were successfully fitted with the mini-scleral lens. Fitting was ideal in 7 eyes and acceptable in 2 eyes. Mean corrected visual acuity by placing the MSD lens without over-refraction was 0.09 (range, 0.00-0.15) LogMAR which was significantly better than the mean BSCVA of 0.38 (range, 0.2-0.6) LogMAR (P = 0.007). The mean root mean square (RMS) of third-order coma and trefoil significantly decreased after MSD contact lens fitting (P = 0.012 and P = 0.015, respectively); however, changes in the fourth-order spherical aberration were not statistically significant (P = 0.336). CONCLUSION Mini-scleral contact lenses may be helpful in the management of visually unsatisfied patients after corneal inlay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrastromal corneal ring segments and posterior chamber phakic intraocular lens implantation for keratoconus correction.

PURPOSE To evaluate the efficacy, safety, and predictability of sequential implantation of Keraring intrastromal corneal ring segments (ICRS) and an Implantable Collamer Lens phakic intraocular lens (pIOL) with corneal relaxing incisions for refractive correction of keratoconus. SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. DESIGN Cohort study. METHODS This study compr...

متن کامل

Ferrara intrastromal corneal rings for the correction of keratoconus.

PURPOSE To evaluate the safety and efficacy of Ferrara intrastromal corneal rings in the treatment of eyes with keratoconus without central corneal scarring. SETTING Vlemma Eye Institute, Athens, Greece. METHODS Twenty-six patients with bilateral keratoconus, clear central corneas, and contact lens intolerance participated in the study. Videokeratographic corneal topography and ultrasonic p...

متن کامل

Intrastromal Corneal Ring Segments for Astigmatism Correction after Deep Anterior Lamellar Keratoplasty

Background. To evaluate the change in corneal astigmatism after intrastromal corneal ring segment (ICRS) implantation in keratoconus patients with previous deep anterior lamellar keratoplasty (DALK). Design was a longitudinal, retrospective, interventional study. The study included 25 eyes of 24 patients with keratoconus who had DALK performed at least two years prior to ICRS implantation. All ...

متن کامل

Intrastromal corneal ring segment implantation with the femtosecond laser in a post-keratoplasty patient with recurrent keratoconus.

A 50-year-old woman had implantation of intrastromal corneal ring segments for recurrent keratoconus 15 years after penetrating keratoplasty. Two segments (0.15 mm and 0.25 mm) were inserted without any intraoperative or postoperative complications, using the femtosecond laser to create the tunnels (superior and inferior). Ten months after the procedure, the uncorrected visual acuity was 20/100...

متن کامل

Comparative Results in a Combined Procedure of Intrastromal Corneal Rings Implantation and Cross-linking in Patients with Keratoconus: A Retrospective Study

INTRODUCTION Corneal thinning disorders caused by keratoconus often lead to protrusion, irregular astigmatism, and even perforation. Keratoconus, like other corneal ectasia, does not have a known cause. Severe cases of keratoconus may require correction or restoration of tectonic integrity of the cornea by surgical means. Intracorneal ring segments are a new modality in the treatment of corneal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016