SU-E-T-497: Study of Restricted Mass Stopping Power Ratio in Small Electron Tube Fields.

نویسندگان

  • S Sugimoto
  • S Ozawa
  • H Takatou
  • K Tokuyama
  • H Maruyama
  • T Yamagishi
  • R Baba
  • K Ebe
  • K Sasai
چکیده

PURPOSE Electron tubes with small radii are useful to treat narrow regions which cannot accommodate normal electron applicators. In small electron fields, it is not trivial to estimate restricted mass stopping power ratio (MSR), which is needed to evaluate dose from ion chamber measurement. We studied MSRs in small electron tube fields using the Monte Carlo simulation. METHODS Electron tubes with radii, 3 and 2.5 cm, were used in this study. Nominal electron energies were 6 and 9 MeV. There were two types of tubes. One has a normal cut but the other has a 45-degree cut. For the normal cut tube, percent depth dose (PDD) in water was evaluated along the center of axis (CAX) of a beam. For the 45-degree cut tube, PDD was evaluated along the vertical line from the intersection of the CAX and the phantom surface with 45-degree gantry angle. The MSRs and mean electron energies were calculated using the Monte Carlo simulation. RESULTS We found good agreement between the measured and calculated PDDs. The changes of mean energies from those in the 10×10 cm2 field at the depth of maximum dose (dmax) were very small for the normal cut electron tubes. For the 45-degree cut tubes, the changes of mean energies at dmax were less than 1 MeV. The MSRs in the normal cut tube fields were almost the same as those in the 10×10 cm2 field at the corresponding depths. The MSRs for the 45-degree cut tubes deviated from those in the 10×10 cm2 by about 1% (1.5 % at most). CONCLUSIONS We evaluated the mean energies and MSRs in small electron tube fields. The deviations of them from the values in the 10×10 cm2 were small. The maximum difference of MSR was 1.5% in 45-degree cut tube fields. This work was supported by KAKENHI (23791449), Japan Society for the Promotion of Science, and Cancer Professional Training Plan, The Ministry of Education, Culture, Sports, Science and Technology, Japan.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of the density, density effect and mean excitation energy in solid-state detectors for small photon fields.

A number of recent publications on small photon beam dosimetry aim at contributing to the understanding of the response of solid-state detectors in small fields. Some of them assign the difference in response to the mass density, or to the electron density, of the sensitive detector material relative to that of water. This work analyses the role of the mass and electron density ([Formula: see t...

متن کامل

Nonlinear Vibration of Smart Micro-Tube Conveying Fluid Under Electro-Thermal Fields

In this study, electro-thermo-mechanical nonlinear vibration and instability of embedded piezoelectric micro-tube is carried out based on nonlocal theory and nonlinear Donnell's shell model. The smart micro-tube made of Poly-vinylidene fluoride (PVDF) is conveying an isentropic, incompressible fluid. The detailed parametric study is conducted, focusing on the remarkable effects of mean flow vel...

متن کامل

Local Field Correction Effect on Dicluster Stopping Power in a Strongly Coupled Two-Dimensional Electron Gas System

We calculate the stopping power for heavy-ion diclusters moving in a strongly coupled two-dimensional electron gas system by using the local field corrected dielectric function at finite temperature. We obtain a parameterized local field correction factor based on a relation between the thermal compressibility and exchange-correlation energy in two-dimension. The interpolated parameter is deriv...

متن کامل

Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams.

Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron equilibrium in the radiation field. It is questionable that stopping-power ratio in dosimetry protocols, obtained for broad photon beams and quasi-electron equilibrium conditions, can be used in the dosimetry of narrow fields while keeping ...

متن کامل

Quantum mechanical proton range in human body

Introduction: Proton therapy delivers radiation to tumor tissue in a much more confined way than conventional photon therapy thus allowing the radiation oncologist to use a greater dose while still minimizing side.   Materials and Methods: protons release most of their energy within the tumor region. As a result, the treating physician can potentially give an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part17  شماره 

صفحات  -

تاریخ انتشار 2012