Efficacy and safety of a collagen matrix for cranial and spinal dural reconstruction using different fixation techniques.

نویسندگان

  • Ruediger Stendel
  • Marco Danne
  • Ingo Fiss
  • Ilse Klein
  • Andreas Schilling
  • Stefanie Hammersen
  • Terttu Pietilae
  • Werner Jänisch
  • Werner Hopfenmüller
چکیده

OBJECT The use of dural grafts is frequently unavoidable when tension-free dural closure cannot be achieved following neurosurgical procedures or trauma. Biodegradable collagen matrices serve as a scaffold for the regrowth of natural tissue and require no suturing. The aim of this study was to investigate the efficacy and safety of dural repair with a collagen matrix using different fixation techniques. METHODS A total of 221 patients (98 male and 123 female; mean age 55.6 +/- 17.8 years) undergoing cranial (86.4%) or spinal (13.6%) procedures with the use of a collagen matrix dural graft were included in this retrospective study. The indications for use, fixation techniques, and associated complications were recorded. RESULTS There were no complications of the dural graft in spinal use. Five (2.6%) of 191 patients undergoing cranial procedures developed infections, 3 of which (1.6%) were deep infections requiring surgical revision. There was no statistically significant relationship between the operative field status before surgery and the occurrence of a postoperative wound infection (p = 0.684). In the 191 patients undergoing a cranial procedure, cerebrospinal fluid (CSF) collection occurred in 5 patients (2.6%) and a CSF fistula in 5 (2.6%), 3 of whom (1.6%) required surgical revision. No patient who underwent an operation with preexisting CSF leakage had postoperative CSF leakage. Postoperative infection significantly increased the risk for postoperative CSF leakage. The collagen matrix was used without additional fixation in 124 patients (56.1%), with single fixation in 55 (24.9%), and with multiple fixations in 42 (19%). There were no systemic allergic reactions or local skin changes. Follow-up imaging in 112 patients (50.7%) revealed no evidence of any adverse reaction to the collagen graft. CONCLUSIONS The collagen matrix is an effective and safe cranial and spinal dural substitute that can be used even in cases of an existing local infection. Postoperative deep infection increases the risk for CSF leakage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical experience with a novel bovine collagen dura mater substitute

BACKGROUND Dural substitutes are used to achieve a watertight closure in situations where adequate closure is not possible .This study was conducted to evaluate the efficacy and safety of use a new collagen matrix dural substitute ( Duradry, Tecnodry, Belo Horizonte MG) in repair or expansion of cranial and spinal dura-mater. METHODS 30 patients operated on between March and September 2008, w...

متن کامل

From surgery to neurosurgery: our experience on the efficacy of fleece-bound sealing (TachoSil®) for dural repair.

AIM To report on our routine use of TachoSil® for dural repair in neurosurgical practice. METHOD TachoSil® has been applied in different fields of surgery thus far. When using TachoSil®, fibrinogen and thrombin is provided locally at the site of the dural defects. Upon contact with fluid, the clotting factors of TachoSil® dissolve and form a fibrin network, which glues the collagen sponge to ...

متن کامل

Cerebellum, brainstem and spinal cord adhesions following basilar impression and Chiari malformation surgery.

Neurosurgical Division of the Hospital Geral Santa Isabel, João Pessoa PB, Brazil;Associated Physician. The true importance of performing a watertight dural closure, for neurological procedures, is to avoid several complications such as cerebrospinal fluid (CSF) leakage, pseudomeningocele (PSM), meningitis, cerebral abscess, tonsilar herniation, hydrocephalus, etc. A variety of materials has be...

متن کامل

The Use of DuraMatrix-Onlay TM for Dural Reconstruction following Craniotomy for Tumor Resection: Results from 100 Consecutive Patients

Objective: Complications from craniotomy in brain tumor patients lead to worse clinical outcomes either from infection, reoperation, or delays in adjuvant therapies. We tested the hypothesis that DuraMatrixOnlay TM Collagen Dura Substitute Membrane potentially could reduce operative complications, and we report the unique characteristics of this onlay product in comparison to primary dural clos...

متن کامل

Evaluation of Non-Watertight Dural Reconstruction with Collagen Matrix Onlay Graft in Posterior Fossa Surgery

OBJECTIVE Many surgeons advocate for watertight dural reconstruction after posterior fossa surgery given the significant risk of cerebrospinal fluid (CSF) leak. Little evidence exists for posterior fossa dural reconstruction utilizing monolayer collagen matrix onlay graft in a non-watertight fashion. Our objective was to report the results of using collagen matrix in a non-watertight fashion fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurosurgery

دوره 109 2  شماره 

صفحات  -

تاریخ انتشار 2008