Influence of Pachymetry and Intraocular Pressure on Dynamic Corneal Response Parameters in Healthy Patients.

نویسندگان

  • Riccardo Vinciguerra
  • Ahmed Elsheikh
  • Cynthia J Roberts
  • Renato Ambrósio
  • David Sung Yong Kang
  • Bernardo T Lopes
  • Emanuela Morenghi
  • Claudio Azzolini
  • Paolo Vinciguerra
چکیده

PURPOSE To evaluate the influence of pachymetry, age, and intraocular pressure in normal patients and to provide normative values for all dynamic corneal response parameters (DCRs) provided by dynamic Scheimpflug analysis. METHODS Seven hundred five healthy patients were included in this multicenter retrospective study. The biomechanical response data were analyzed to obtain normative values with their dependence on corrected and clinically validated intraocular pressure estimates developed using the finite element method (bIOP), central corneal thickness (CCT), and age, and to evaluate the influence of bIOP, CCT, and age. RESULTS The results showed that all DCRs were correlated with bIOP except deflection amplitude (DefA) ratio, highest concavity (HC) radius, and inverse concave radius. The analysis of the relationship of DCRs with CCT indicated that HC radius, inverse concave radius, deformation amplitude (DA) ratio, and DefA ratio were correlated with CCT (rho values of 0.343, -0.407, -0.444, and -0.406, respectively). The age group subanalysis revealed that primarily whole eye movement followed by DA ratio and inverse concave radius were the parameters that were most influenced by age. Finally, custom software was created to compare normative values to imported examinations. CONCLUSIONS HC radius, inverse concave radius, DA ratio, and DefA ratio were shown to be suitable parameters to evaluate in vivo corneal biomechanics due to their independence from IOP and their correlation with pachymetry and age. The creation of normative values allows the interpretation of an abnormal examination without the need to match every case with another normal patient matched for CCT and IOP. [J Refract Surg. 2016;32(8):550-561.].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corneal Pachymetry measured with Pentacam and CorvisST in Normal and Keratoconic Eyes

Purpose: To evaluate the agreement of pachymetry data provided by a new instrument to measure intraocular pressure (IOP) and the corneal biomechanical response with the values provided by Pentacam in healthy and keratoconic eyes. Methods: Fifty-four right eyes from 54 healthy patients (32 females, 22 males) and 82 eyes from 43 keratoconus patients (20 females, 23 males) were included in the stu...

متن کامل

Effect of diabetes mellitus on biomechanical parameters of the cornea.

PURPOSE To compare parameters of biomechanical response of the human cornea measured as corneal hysteresis (CH) and corneal resistance factor (CRF) in patients with diabetes mellitus and healthy control subjects. SETTING Department of Ophthalmology, Assaf Harofeh Medical Center, Zerifin, Israel. METHODS In the right eye of each participant, the CH, CRF, Goldmann-correlated intraocular press...

متن کامل

Correlations between parameters of aqueous humor dynamics and the influence of central corneal thickness.

PURPOSE The individual parameters of aqueous humor dynamics may influence each other to maintain intraocular pressure (IOP) homeostasis. Central corneal thickness (CCT) is known to be associated with onset and progression of glaucoma and can potentially influence the individual parameters of aqueous humor dynamics that maintain IOP. This study investigates the correlation between parameters of ...

متن کامل

بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن

To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...

متن کامل

Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.

PURPOSE To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. PATIENTS AND METHODS Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 32 8  شماره 

صفحات  -

تاریخ انتشار 2016