The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS

ثبت نشده
چکیده

A new product (Application 460B-00) from Agilent Technologies/WassonECE uses a 5973N GC/MSD (gas chromatograph/mass selective detector) for the determination of trace levels of impurities that are moderate-to-low carbon-content such as oxygenates, mercaptans, sulfides, arsine, and phosphine in ethylene and propylene. This work describes the performance of Application 460B-00 with respect to linearity, repeatability, and limits of detection (for most compounds, low parts-per-billion). Compared to determinations with GC/FID (flame ionization detection) or GC/TCD The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS Agilent Technologies/Wasson ECE Monomer Analyzer

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sub-ppb detection limits for hydride gas contaminants using GC-ICP-QQQ

Hydride gases, such as phosphine and arsine, are important contaminants in process chemicals used in both the petrochemical and semiconductor industries. For example, the presence of phosphine, arsine, hydrogen sulfide and carbonyl sulfide in polymer grade ethylene or propylene can have a deleterious effect on catalysts used in the production of polypropylene plastics. Accurate data on the conc...

متن کامل

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Ammonium hydroxide (NH4OH) is a chemical used in the manufacture of semiconductor devices, and must therefore be analyzed for trace metal impurities. The direct analysis of undiluted (20%) NH4OH using ICP-MS is challenging because its high vapor pressure causes plasma instability. However, dilution of the samples would degrade detection limits, so the ability to directly analyze 20% NH4OH is im...

متن کامل

An Integrated AHP-PROMETHEE Method for Selecting the most Suitable Ethylene Propylene Diene Termonomer

This paper considers the problem of selecting the most appropriate ethylene propylene diene monomer (EPDM), which is a polyolefin with a variety of usages in different areas. The metallocene catalyst, bis(2-phenyl indenyl) zirconium dichloride ((2-PhInd)2ZrCl2) was synthesized by a modified method and applied to the terpolymerization of ethylene, propylene, and 5-ethylidiene-2-norbornene (ENB)....

متن کامل

سنتز، جداسازی و شناسایی Isonol C100 تهیه ‌شده از طریق پروپوکسیله کردن آنیلین

N,N’-bis(2-hydroxypropyl)aniline (Isonol C100) is an alkanolamine. This compound is intended to increase the chain length of curing composite solid propellants, stabilize and soften the double base propellants, and assist in the softening of the ethyl cellules. Isonol C100 was synthesized through the reaction of propylene oxide and aniline at a pressure of 7 bar, a temperature of 125 &deg...

متن کامل

Direct measurement of metallic impurities in 20% ammonium hydroxide by Agilent 7700s ICP-MS

Ammonium hydroxide (NH4OH) is a chemical used in the manufacture of semiconductor devices, and must therefore be analyzed for trace metal impurities. The direct analysis of undiluted (20%) NH4OH using ICP-MS is challenging, because its high vapor pressure causes plasma instability. However, dilution of the samples would degrade detection limits, so the ability to directly analyze 20% NH4OH is i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005