Effects of pulse rate and electrode array design on intensity discrimination in cochlear implant users.

نویسندگان

  • Heather A Kreft
  • Gail S Donaldson
  • David A Nelson
چکیده

The effects of pulse rate on intensity discrimination were evaluated in 14 subjects with Clarion C-I cochlear implants. Subjects had a standard [Clarion spiral electrode array (SPRL group)] or perimodiolar electrode array [Clarion HiFocus electrode array with electrode positioning system (HF+EPS group)]. Weber fractions for intensity discrimination [ Wf(dB)= 10 log deltaI/I] were evaluated at five levels over dynamic range at each of three pulse rates (200, 1625 and 6500 pps) using monopolar stimulation. Weber fractions were smaller for 200 pps stimuli than for 1625 or 6500 pps stimuli in both groups. Weber fractions were significantly smaller for SPRL subjects (mean Wf(dB) = -9.1 dB) than for HF+EPS subjects (mean Wf(dB) = -6.7 dB). Intensity difference limens (DLs) expressed as a percentage of dynamic range (DR) (deltaI%DR= deltaI/DRdB* 100) did not vary systematically with pulse rate in either group. Larger intensity DLs combined with smaller dynamic ranges led to fewer intensity steps over the dynamic range for HF+EPS subjects (average 9 steps) compared to SPRL subjects (average 23 steps). The observed effects of pulse rate and electrode array design may stem primarily from an inverse relationship between absolute current amplitude and the size of intensity DLs. The combination of smaller dynamic ranges and larger Weber fractions in HF+EPS subjects could be the result of increased variability of neural outputs in these subjects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Psychophysics experimental software to evaluate electrical pitch discrimination in Nucleus cochlear implanted patients

Multichannel electrode array design in cochlear implants has evolved into two major categories: straight and perimodiolar electrodes. When implanted, the former lies along the outer wall of the scala tympani, while the later are located closer to the modiolus, where the neural ends are. Therefore, a perimodiolar position of the electrode array could be expected to result in reduced stimulus thr...

متن کامل

EFFECT OF A UDITORY-VERBAL REHABILITATION ON VOICE PARAMETERS IN CHILD COCHLEAR IMPLANT USERS

This study aimed to evaluate the effects of auditory-verbal rehabilitation on voice parameters after implantation with cochlear implants 2 and 5 months after rehabilitation and compare them with normal voice children (under 12 years of age). A perceptive and electroacoustic evaluation of voice was carried out through a digital analysis after implantation and rehabilitation. The study was pe...

متن کامل

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

The upper limit of temporal pitch for cochlear-implant listeners: stimulus duration, conditioner pulses, and the number of electrodes stimulated.

Three experiments studied discrimination of changes in the rate of electrical pulse trains by cochlear-implant (CI) users and investigated the effect of manipulations that would be expected to substantially affect the pattern of auditory nerve (AN) activity. Experiment 1 used single-electrode stimulation and tested discrimination at baseline rates between 100 and 500 pps. Performance was genera...

متن کامل

Electrode interaction in cochlear implant recipients: comparison of straight and contour electrode arrays.

The degree of overlap among cochlear nerve fibers stimulated by different electrodes results in electrode interaction, which has been shown to have a significantly deleterious effect on speech recognition performance in multi-electrode cochlear implant users. The Nucleus CI24R(CS) Contour array, which lies substantially closer to the modiolus than the CI24M straight array, is expected to exhibi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 116 4 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2004