Elimination of Nyquist ghosting caused by read-out to phase-encode gradient cross-terms in EPI.
نویسندگان
چکیده
Echo-planar imaging (EPI) commonly suffers from ghosting artifacts caused by zero- or first-order phase differences between the odd and even echoes that constitute an EPI dataset. Small-bore imaging systems with shielded gradients may suffer significantly from cross-term eddy currents due to the high degree of manufacturing precision required in such systems compared to larger whole-body coils. A Nyquist ghost caused by cross-term eddy current contributions from the read-out to the phase-encode axis was identified in a small-bore system and characterized using a modified EPI experiment and a computer simulation. The artifact was corrected for using both a postprocessing approach and compensation blips along the phase-encode axis. Correction using compensation blips proved to be a more effective strategy to reduce this artifact than the postprocessing method used.
منابع مشابه
Correction of EPI Nyquist ghosting caused by the non-uniform frequency response of the MRI receiver chain
O. Josephs, N. Weiskopf, R. Deichmann Wellcome Department of Imaging Neuroscience, University College London, London, United Kingdom Introduction For the majority of rectilinear echo-planar imaging (EPI) sequences, every other phase-encoding (PE) line is acquired with an inverted readout (RO) gradient. Any effect that leads to a signal dependence on the RO direction and thus to a systematic dif...
متن کاملImproving EPI Imaging Quality and Sound Levels with Bandwidth Selection
K. McMahon, A. Pringle, M. Eastburn, D. Maillet Centre for Magnetic Resonance, University of Queensland, Brisbane, Queensland, Australia Introduction: Echo planar imaging (EPI) is a rapid sequence that has been applied with great success to diffusion, perfusion and functional magnetic resonance imaging (fMRI) of the brain. However, the oscillating gradients in EPI can produce artefacts such as ...
متن کاملOptimized acquisition strategy for reference-free reduction of Nyquist ghosting in EPI at 7 T
Introduction fMRI commonly employs the echo planar imaging (EPI) sequence because of its favourable sensitivity, and its very high sampling efficiency which allows ‘single-shot’ imaging of a brain slice within typically ~70 ms. This is achieved by traversing k-space under an oscillating readout gradient, and so every other k-space line needs to be time-reversed (‘flipped’) before Fourier recons...
متن کاملRobust EPI Nyquist ghost elimination via spatial and temporal encoding.
Nyquist ghosts are an inherent artifact in echo planar imaging acquisitions. An approach to robustly eliminate Nyquist ghosts is presented that integrates two previous Nyquist ghost correction techniques: temporal domain encoding (phase labeling for additional coordinate encoding: PLACE and spatial domain encoding (phased array ghost elimination: PAGE). Temporal encoding modulates the echo plan...
متن کاملMinimization of Nyquist ghosting for echo-planar imaging at ultra-high fields based on a "negative readout gradient" strategy.
PURPOSE To improve the traditional Nyquist ghost correction approach in echo planar imaging (EPI) at high fields, via schemes based on the reversal of the EPI readout gradient polarity for every other volume throughout a functional magnetic resonance imaging (fMRI) acquisition train. MATERIALS AND METHODS An EPI sequence in which the readout gradient was inverted every other volume was implem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 47 2 شماره
صفحات -
تاریخ انتشار 2002