Efficacy of intraoperative transesophageal echocardiography in a case of protamine shock during transcatheter aortic valve implantation

نویسندگان

  • Akihisa Kataoka
  • Yusuke Watanabe
  • Shutaro Seki
  • Shintaro Takamura
  • Hirofumi Hioki
  • Hiroyuki Kyono
  • Shigehito Sawamura
  • Ken Kozuma
چکیده

Here, we report the case of a patient who developed protamine shock during a transcatheter aortic valve implant (TAVI) procedure, which was diagnosed by intraoperative transesophageal echocardiography (TEE). A 77-year-old man with symptomatic severe aortic stenosis and reduced left ventricular (LV) function underwent TAVI under general anesthesia. During the procedure, a transcatheter heart valve (THV) was deployed via the transfemoral approach, without any other major complications. The entire device system was then removed, and protamine sulfate was administered intravenously in 2 min. Two minutes after the protamine administration, severe hypotension occurred. TEE did not reveal THV malfunction or any other major complications. However, comparison of the TEE image obtained before protamine administration and that obtained 2 min after protamine administration showed right ventricular (RV) dilatation, RV free wall motion abnormality, and LV volume reduction, without any electrocardiographic changes. We diagnosed this as protamine shock and bolus infusions of phenylephrine and norepinephrine were administered, and chest compressions were initiated immediately. After 1 min, hypotension as well as the right and left ventricular size and dysfunction immediately reverted to baseline. The severe systemic hypotension resolved as well. Thereafter, he recovered from anesthesia without other complications. This case showed the clinical features of protamine shock with acute pulmonary hypertension. The TEE images, in this case, should be a reminder for all doctors who perform intraoperative TEE for patient monitoring when they perform procedures to treat structural heart diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Case Report : Post transcatheter aortic valve replacement shock : Value of multimodal imaging

Complications resulting from the delayed clinical presentation of a left main coronary artery obstruction can be catastrophic. This case report presents a 73-year-old woman with severe aortic stenosis who underwent transcatheter aortic valve replacement with a core valve who, approximately 20 minutes after heparin reversal with protamine, became hypotensive and was unresponsive to vasopressor a...

متن کامل

Anesthetic management for percutaneous aortic valve implantation: an overview of worldwide experiences

Transcatheter aortic valve implantation is an emergent technique for high risk patients with aortic stenosis. Transcatheter aortic valve implantation poses significant challenges about its management, due to the procedure itself (i.e. the passage of large stiff sheaths in diseased vessels, the valve dilatation and the prosthesis positioning during a partial cardiac standstill) and the populatio...

متن کامل

Implantation of transcatheter aortic valve prosthesis through the ascending aorta concomitant with coronary artery bypass grafting without cardiopulmonary bypass

INTRODUCTION The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. OBJECTIVE The aim of this study is to approach the implantation of transcatheter aortic valve throug...

متن کامل

FDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device.

can Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. J Am Soc Echocardiogr 1999;12: 884–900. 21. Wong DT, Bertaso AG, Liew GY, Thomson VS, Cunnington MS, Richardson JD et al. Relationship of aortic annular eccentricity and paravalvular regurg...

متن کامل

Prognostic Implications of Asymmetric Morphology in Transcatheter Aortic Valve Implantation: a Case Report Implicaciones pronósticas de la morfologı́a asimétrica en la implantación de prótesis aórticas transcatéter: a propósito de un caso

Transcatheter implantation of aortic valve prostheses is being performed with increasing frequency in patients with severe symptomatic aortic stenosis who are at high surgical risk. Either a transfemoral or a transapical approach is employed. Complications related to the procedure are relatively uncommon, but they provide information that is very useful for broadening our knowledge of the patho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2016