Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula.

نویسندگان

  • Edmondo Borasio
  • Julian Stevens
  • Guy T Smith
چکیده

PURPOSE To describe a new formula, BESSt, to estimate true corneal power after keratorefractive surgery in eyes requiring cataract surgery. SETTING Moorfields Eye Hospital, London, United Kingdom. METHODS The BESSt formula, based on the Gaussian optics formula, was developed using data from 143 eyes that had keratorefractive surgery. The formula takes into account anterior and posterior corneal radii and pachymetry (Pentacam, Oculus) and does not require pre-keratorefractive surgery information. A software program was developed (BESSt Corneal Power Calculator), and corneal power was calculated in 13 eyes that had keratorefractive surgery and required cataract surgery. RESULTS In the eyes having phacoemulsification, target refractions calculated with the BESSt formula were statistically significantly closer to the postoperative manifest refraction (mean deviation 0.08 diopters [D] +/- 0.62 [SD]) than those calculated with other methods as follows: history technique (-0.07 +/- 1.92 D; P = .05); history technique with double-K adjustment (0.13 +/- 2.39 D; P = .05); Holladay 2 with K-values estimated with the contact lens method (-0.76 +/- 1.36 D; P = .03); Holladay 2 with K-values from Atlas topographer (Humphrey) (-0.55 +/- 0.61 D; P<.01). Using the BESSt formula, 46% of eyes were within +/-0.50 D of the intended refraction and 100% were within +/-1.00 D. CONCLUSIONS The BESSt formula was statistically significantly more accurate than the other techniques tested. Thus, it could significantly improve intraocular lens power calculation accuracy after keratorefractive surgery, especially when pre-refractive surgery data are unavailable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Pentacam keratometric values unreliable for IOL power calculation after refractive surgery.

Pentacam Keratometric Values Unreliable for IOL Power Calculation After Refractive Surgery To the Editor: We read with interest the article by Gonen et al,1 which appeared in the August 2012 issue of the Journal of Refractive Surgery, on their study comparing keratometric data from 200 patients evaluated for refractive surgery using four different devices—an automated keratometer (KR 8800 [Topc...

متن کامل

The Comparison of Central and Mean True-Net Power (Pentacam) in Calculating IOL-Power After Refractive Surgery

PURPOSE To compare the accuracy of central true net corneal power (cTNP) and mean true net corneal power (mTNP) of the Pentacam system to give a keratometry (K) reading for calculating IOL (intraocular lens) power in eyes following refractive surgery. METHODS Refraction, an automated K-reading (Km), cTNP and mTNP were measured for 15 eyes that required cataract surgery and had previously unde...

متن کامل

The Camellin - Calossi formula

Nowadays is well stated that after keratorefractive surgery, without a special correction, the intraocular lens (IOL) power is usually inaccurate. The article by Kenneth J. Hoffer1 which appeared in the first JanuaryMarch 2010 issue of the Journal of Emmetropia is an excellent review of recently published studies that analyze and try to solve the problems to calculate IOL power in eyes with pri...

متن کامل

Intraocular lens power calculatio n after corneal refractive surgery

Current Opinion in Ophthalmology 2008, 19:357–362 Purpose of review Corneal refractive procedures have become increasingly popular over the past decade allowing patients to have excellent uncorrected visual acuity and spectacle independence. As these individuals mature, many will eventually undergo cataract surgery. With the advances in modern cataract surgery and lens implant technology, parti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 32 12  شماره 

صفحات  -

تاریخ انتشار 2006