Polymerization time for a microwave-cured acrylic resin with multiple flasks.
نویسندگان
چکیده
This study aimed at establishing the polymerization time of a microwave-cured acrylic resin (AcronTM MC), simultaneously processing 2, 4, and 6 flasks. Required time was measured according to the parameters: monomer release in water, Knoop hardness, and porosity. Samples were made with AcronTM MC in different shapes: rectangular (32 x 10 x 2.5 mm) for monomer release and porosity; and half-disc (30 mm in diameter x 4 mm in height) for Knoop hardness. There were four experimental groups (n = 24 per group): G1) one flask (control); G2) two flasks; G3) four flasks, and G4) six flasks. At first, polymerization protocol was similar for all groups (3 min/450 W). Time was then adjusted for G2, G3, and G4, based on monomer release evaluation in the control group, obtained by spectrophotometer Beckman DU-70, with emitting wave of 206 nm. Knoop hardness test was performed using a Shimadzu HMV 2000 hardness tester, and 10 indentations were performed on each specimen's surface. Porosity was assessed after specimens were immersed in black ink and the pores counted in a microscope. Results showed that the complete polymerization of the resin occurred in 4.5 min for two flasks (G2); 8.5 min for four flasks (G3); and 13 min for six flasks (G4), all with 450 W. Statistical analysis revealed that the number of flasks does not interfere with polymerization, Knoop hardness, and porosity of the resin. Results showed that polymerization of microwave-curing resin with more than one flask is a viable procedure, as long as polymerization time is adjusted.
منابع مشابه
Evaluation of Bond Strength of Acrylic Teeth to Denture Base using Different Polymerization Techniques: A Comparative Study
BACKGROUND Acrylic teeth have long been used in the treatment of a complete denture. One of the primary advantages of acrylic teeth is their ability to adhesively bond to the denture base resins. Although the bonding seems satisfactory, however, bond failures at the acrylic teeth and denture base resin interface are still a common clinical problem in prosthodontics. The purpose of this study wa...
متن کاملEffect of intrinsic pigmentation on the flexural strength of a microwave-cured acrylic resin.
This study investigated the effect of intrinsic pigmentation on the transverse strength of a microwave-cured acrylic resin. Forty transverse strength specimens were fabricated according to ADA specification #12 and divided into 5 groups. No fibers were added to group I (GI, control group); acrylic stain (AS) was added to GII and GIII in concentrations of 0.5 and 1.5% w/w, respectively; acrylic ...
متن کاملWater sorption of heat-polymerized acrylic resins processed in mono and bimaxillary flasks.
This study evaluated water sorption in heat-polymerized acrylic resins processed in monomaxillary flasks by water bath and in bimaxillary flasks by microwave energy and water bath. Fifty heat-polymerized acrylic resin specimens were fabricated according to the 12th specification of the American Dental Association and assigned to 3 groups: group 1 was processed by water bath in monomaxillary met...
متن کاملThe difference of acrylic resin residual monomer levels with various polymerization method
Background: After polymerization process, heat cured acrylic resin denture base actually still contains residual monomers that can become potential irritants later in oral cavity. Polymerization process is essential to obtain acrylic resin which can meet the requirements of the biocompatible and good physical properties. To meet the requirements, there are several methods of polymerization proc...
متن کاملComparison of the Transverse Strength of Six Acrylic Denture Resins
Aim: The aim of this study was to evaluate the transverse strength of three kinds of heat-cured acrylic resin (Meliodent HC, Acron HC, Lucitone 199); one kind of microwave-cured acrylic resin (Acron MC); one kind of visible light-cured resin (Triad VLC); and one kind of self-cured acrylic resin (Meliodent SC). Method: A total of 60 specimens (65 mm x 10 mm x 3 mm) were fabricated, ten from each...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian oral research
دوره 18 1 شماره
صفحات -
تاریخ انتشار 2004