Gadolinium-DTPA-enhanced MR imaging of spinal neoplasms: preliminary investigation and comparison with unenhanced spin-echo and STIR sequences.

نویسندگان

  • G K Stimac
  • B A Porter
  • D O Olson
  • R Gerlach
  • M Genton
چکیده

Unenhanced T1- and T2-weighted spin-echo, short inversion time inversion recovery (STIR), and gadolinium-DTPA (Gd-DTPA)-enhanced spin-echo and STIR imaging techniques were used in 20 patients as part of a multicenter study to assess the safety and efficacy of Gd-DTPA in spinal imaging. Five patients had normal MR scans. Of those with lesions, both Gd-DTPA-enhanced T1-weighted spin-echo and unenhanced STIR scans improved detection and evaluation of spinal tumors over conventional spin-echo methods, particularly T2-weighted spin echo, by providing higher tissue contrast in shorter imaging times. The Gd-DTPA-enhanced T1-weighted spin-echo scans were most helpful in evaluating intradural tumors, whereas STIR sequences were most effective for extradural tumors and bone metastases. In most cases, Gd-DTPA-enhanced T1-weighted spin-echo scans best delineated tumor margins, and the enhancement was helpful in suggesting a cellular or active nature of the lesions. In some cases, the enhancement resulted in a more homogeneous and thus less abnormal-appearing marrow in vertebrae involved by tumor; therefore, a precontrast T1-weighted spin-echo scan is necessary in all patients who are to be studied with Gd-DTPA. A combined approach that uses T1-weighted spin-echo, Gd-DTPA-enhanced T1-weighted spin-echo, and STIR images currently appears optimal for MR imaging of spinal neoplasms. T2-weighted spin-echo images add information only in occasional cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gadolinium-DTPA in MR imaging of glioblastomas and intracranial metastases.

In 14 patients with the diagnosis of glioblastoma (n = 7) or intracranial metastases (n = 7), magnetic resonance (MR) imaging was performed using a variety of spin-echo (SE) pulse sequences before and after intravenous injection of 0.1 mmol gadolinium-DTPA (Gd-DTPA) per kilogram of body weight. In 10 patients, tumor tissue could not be adequately differentiated from perifocal edema on unenhance...

متن کامل

Gadolinium-DTPA and MR imaging of pituitary adenoma: a preliminary report.

Gadolinium-DTPA MR imaging (Gd-MR), unenhanced MR imaging, and contrast-enhanced CT studies were compared prospectively in six patients with surgically confirmed pituitary adenomas and three patients without sellar pathology to determine the utility of Gd-MR in the diagnosis of pituitary adenoma. In normal patients, the pituitary gland, cavernous sinus, and infundibulum enhanced by T1 shortenin...

متن کامل

Inflammation in ankylosing spondylitis: a systematic description of the extent and frequency of acute spinal changes using magnetic resonance imaging.

BACKGROUND Magnetic resonance imaging (MRI) is increasingly used to detect inflammation in the spine of patients with ankylosing spondylitis (AS). OBJECTIVES To detect differentially the presence and extent of inflammation in the three spinal segments of patients with AS by MRI. METHODS In 38 patients with active AS, acute spinal lesions were assessed by T(1) weighted, gadolinium enhanced, ...

متن کامل

Detection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging.

OBJECTIVE The purpose of this study was to compare breath-hold three-dimensional (3D) rapid gradient-echo (GRE) MR imaging obtained before and after gadolinium chelate injection with T2-weighted fast spin-echo and T2-weighted breath-hold fast spin-echo (BHFSE) MR imaging in the detection of focal hepatic masses. SUBJECTS AND METHODS Fifty-three patients with 108 focal hepatic masses had, pros...

متن کامل

Low-cost high-resolution fast spin-echo MR of acoustic schwannoma: an alternative to enhanced conventional spin-echo MR?

PURPOSE To determine whether unenhanced high-resolution T2-weighted fast spin-echo MR imaging provides an acceptable and less expensive alternative to contrast-enhanced conventional T1-weighted spin-echo MR techniques in the diagnosis of acoustic schwannoma. METHODS We reviewed in a blinded fashion the records of 25 patients with pathologically documented acoustic schwannoma and of 25 control...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 151 6  شماره 

صفحات  -

تاریخ انتشار 1988