Longitudinal evaluation of the seal of IRM root end fillings.
نویسندگان
چکیده
IRM has been recommended for root end filling during endodontic surgery. This study evaluated the seal of IRM root end fillings prepared with various powder to liquid ratios (P:L) at extended time intervals using a fluid filtration method. The P:L of IRM evaluated included 2, 3, 4, 5, and 6 g/ml and the P:L which resulted from the manufacturer's recommended scoop and dropper. Ten teeth were evaluated for microleakage for each group at 1, 2, 3, 4, 8, and 12 wk after insertion. There were no significant differences in the microleakage of any of the various P:L groups at weeks 3, 8, and 12. These results suggest that higher P:L of IRM than those previously recommended for temporary restorations and for endodontic access preparations may be acceptable for root end fillings. IRM of higher P:L has other advantages such as ease of placement and decreased setting time, toxicity, and solubility.
منابع مشابه
Super-EBA and IRM as root-end fillings in periapical surgery with ultrasonic preparation: a prospective randomized clinical study of 206 consecutive teeth.
OBJECTIVE This study evaluated the treatment outcome after periapical surgery with the use of 2 different retrograde root-filling materials and the influence of 3 pre- and perioperative variables on the periapical healing. STUDY DESIGN Two hundred six teeth in 164 patients were randomly allocated to receive either IRM or Super-EBA as a retrograde root-end seal. The teeth were reviewed 12 mont...
متن کاملAn investigation of microleakage from root-end fillings in ultrasonic retrograde cavities with or without finishing: a quantitative analysis.
OBJECTIVE The aim of this study was to make a quantitative assessment of the sealing ability of Super-EBA, IRM, and Pro Root MTA root-end fillings subjected to 3 different finishing techniques. STUDY DESIGN Eighty-one ultrasonically prepared root-end cavities in human canines were separated randomly into 3 test groups of 27 roots each. The cavities were filled with Super-EBA, IRM, or Pro Root...
متن کاملMicroleakage of root-end filling materials.
The purpose of this study was to evaluate the microleakage of various root-end filling materials using a fluid filtration system. Sixty extracted human single-rooted teeth were used. The crowns were removed, the canals prepared, and root-end fillings placed. The samples were divided into two control and five experimental groups. The root-end filling materials tested were: amalgam, Intermediate ...
متن کاملEvaluation of Marginal Adaptation of Root-End Filling Materials Using Scanning Electron Microscopy
INTRODUCTION The importance of perfect apical seal in endodontics, more specifically in periradicular surgery, is the motivation/reason for development of root-end filling materials with favorable physical, chemical and biological characteristics. The aim of this in vitro study was to evaluate the marginal adaptation of root-end filling materials using scanning electron microscopy. MATERIALS ...
متن کاملMicrobial leakage of Cavit, IRM, and Temp Bond in post-prepared root canals using two methods of gutta-percha removal: an in vitro study.
The aim of this study was to evaluate the integrity of the coronal seal of Temp-Bond and compare it to Cavit and IRM after post space preparation using S. faecalis as a microbial tracer. In addition, the affect of two methods of gutta percha removal on the apical seal of root canal fillings was also evaluated. Forty extracted human single rooted teeth were prepared chemomechanically and obturat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endodontics
دوره 20 5 شماره
صفحات -