A non-invasive method for estimating lung function
نویسندگان
چکیده
Andrew D Farmery and Clive E W Hahn are with Nuffield Department of Anaesthetics, University of Oxford, Oxford, UK. Email: andrew. [email protected] / [email protected] Conventional methods for monitoring lung function usually require complex gas analysers and the cooperation of the patient. Therefore, they are not compatible with the crowded environment of the intensive care unit (ICU) or operating theatre, where patient cooperation is usually impossible. However, it is precisely these patients that would benefit the most from an accurate monitoring of lung function. This paper develops a compact and non-invasive system for the measurement and monitoring of lung function in a clinical setting, such as lung volume, airway dead space volume and pulmonary blood flow. In contrast with conventional methods, the compact apparatus and non-invasive nature of the proposed method allow it to be used in the ICU, as well as in general clinical settings. The system implements a breath-by-breath computer ventilation model using a non-invasive technique, in which a tracer gas is injected into the patient’s inspired breath. Experimental results are shown for both an artificial lung and a healthy volunteer. Our findings show that the proposed technique has several advantages over the conventional method for the estimation of lung function.
منابع مشابه
Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملNo needle to fear: An approach to needle phobic patients
18F-FDG is the most commonly used radioisotope in PET scanning and is administered intravenously. When patients cannot cannulated, there are limited options available for functional tumour assessment. A fifty year old male presented for investigation of a suspected lung carcinoma identified during investigation of pneumonia. The patient had a severe needle phobia, intellectual dis...
متن کاملAnalysis of different model-based approaches for estimating dFRC for real-time application
BACKGROUND Acute Respiratory Distress Syndrome (ARDS) is characterized by inflammation, filling of the lung with fluid and the collapse of lung units. Mechanical ventilation (MV) is used to treat ARDS using positive end expiratory pressure (PEEP) to recruit and retain lung units, thus increasing pulmonary volume and dynamic functional residual capacity (dFRC) at the end of expiration. However, ...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملValidity of Spo2/Fio2 Ratio in Detection of Acute Lung Injury and Acute Respiratory Distress Syndrome
Introduction: One ofdiagnostic criteria for Acute Lung Injury and Acute Respiratory Distress Syndrome is pao2/fio2 (PF) ratio 300 for ALI or 200 for ARDS. This criteria requires invasive arterial sampling. Measurement of Spo2/Fio2 (SF) ratio by pulseoximetry may be a reliable non invasive alternative to the PF ratio. Methods and Materials: In a cross sectional study we enrolled 105 sample o...
متن کامل