Subsurface Targets Imaging with an Improved Back- Projection Algorithm

نویسنده

  • Alireza Akbari
چکیده

In ground penetrating radar (GPR) imaging, a single point target appears as a hyperbolic curve in the space-time image. In order to focus the hyperbolic curves in GPR images, first, the back-projection (BP) imaging algorithm was introduced. This standard BP imaging algorithm, was accompanied by a lot of artifacts, which have adverse effects on targets detection. Second, an improved BP imaging algorithm, based on cross-correlation between received signals for suppression artifacts, was proposed here. Third, to improve the quality of BP imaging algorithm, a weight factor was designed by analyzing the statistical character of receiving data for each point in regions of imaging. This proposed algorithm was applied on the simulation and the real GPR data and the results showed that the proposed BP imaging algorithm has superior suppression artifacts and produces images with high quality and resolution. In order to quantitatively describe the imaging results on the effect of artifact suppression, focusing parameter was evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An improved back projection imaging algorithm for subsurface target detection

An improved back projection imaging algorithm for subsurface target detection is presented in this paper. Firstly, the characteristic of the scattering data at each time-delay curve in the traditional back projection imaging procedure is analyzed. Secondly, a weight factor is designed for each focal point and an improved back projection imaging algorithm is presented. Thirdly, the simulation of...

متن کامل

An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm

Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study, first, the EPID calibration curve and correction coefficients for field size were obtained from EPID and ionization chamber. Second, the...

متن کامل

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Ultrawide-Band Synthetic Aperture Radar for Detection of Unexploded Ordnance: Modeling and Measurements

Electromagnetic (EM) scattering from subsurface unexploded ordnance (UXO) is investigated both theoretically and experimentally. Three EM models are considered: the multilevel fast multipole algorithm (MLFMA), the method of moments (MoM), and physical optics (PO). The relative accuracy of these models is compared for several scattering scenarios. Moreover, the model results are compared to data...

متن کامل

A Data Focusing method for Microwave Imaging of Extended Targets

This paper presents a data focusing method (DFM) to image extended targets using the multiple signal classification (MUSIC) algorithm. The restriction on the number of transmitter-receiver antennas in a microwave imaging system deteriorates profiling an extended target that comprises many point scatterers. Under such situation, the subspace-based linear inverse scattering methods, like the MUSI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014