Total knee arthroplasty with an oxidised zirconium femoral component: a 5-year follow-up study.

نویسندگان

  • Derek H Park
  • Julian Leong
  • Stephen J Palmer
چکیده

PURPOSE To report the early results of the Oxinium Genesis II prosthesis with an oxidised zirconium femoral component in 55 patients. METHODS 71 knees in 21 men and 34 women aged 32 to 75 (mean, 55) years were evaluated; 16 of the patients had bilateral staged total knee replacements with a mean interval of 9 (range, 6-16) months between surgeries. The indications for surgery included osteoarthritis (n=57), rheumatoid arthritis (n=13) and revision from a unicompartmental knee replacement for osteoarthritis (n=1). Postoperatively, patients were evaluated using the Knee Society score (KSS), the modified Oxford Knee Score, and the SF-12 health survey, as were component position, leg and knee alignment, and prosthesis-bone interface or fixation on radiographs. RESULTS The mean follow-up was 62 (range, 51-88) months. The mean KSS, Oxford Knee Score, and SF-12 physical component score improved significantly. Radiolucent lines (<2 mm) were noted in the tibial cement-bone interface in 17 knees (most commonly in zones 4 and 1) and in the femoral cement-bone interface in one knee. The alignment of the knees and positioning of the components were acceptable. There were no revisions for septic or aseptic loosening. CONCLUSION Early results of the Oxinium Genesis II prosthesis are comparable to the standard total knee prostheses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Five-year comparison of oxidized zirconium and cobalt-chromium femoral components in total knee arthroplasty: a randomized controlled trial.

BACKGROUND In vitro analysis has shown that oxidized zirconium on ultra-high molecular weight polyethylene has better wear properties than cobalt-chromium on ultra-high molecular weight polyethylene. The purpose of this study was to determine if oxidized zirconium femoral components performed better than cobalt-chromium in vivo and if the use of oxidized zirconium components had clinical advers...

متن کامل

Total Knee Replacement with an Oxidised Zirconium Femoral Component

This open-access article is published and distributed under the Creative Commons Attribution NonCommercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article witho...

متن کامل

Hybrid total knee arthroplasty: 10- to 16-year follow-up.

A cementless femoral component may allow for a smaller surgical incision when a minimally invasive approach is used during primary total knee arthroplasty. Fixation by cement is the gold standard for total knee arthroplasty. The results of cementless total knee arthroplasty are mixed. Cementless femoral components have done well. Although some tibial components have performed well at long-term ...

متن کامل

Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.

Oxidised zirconium (OxZi) has been developed as an alternative bearing surface for femoral heads in total hip arthroplasty (THA). This study has investigated polyethylene wear, functional outcomes and complications, comparing OxZi and cobalt-chrome (CoCr) as part of a three-arm, multicentre randomised controlled trial. Patients undergoing THA from four institutions were prospectively randomised...

متن کامل

Stress Fracture of the Lateral Femoral Condyle afterTotal Knee Arthroplasty

Background: This is to assess one of the rare complications after total knee replacement and to assess risk factors of failure.Methods: 11 patients with varus knee and an average age of 67 years underwent TKA between 2005 and 2013. All patients returned with a sudden sharp knee pain, disability to walk and significant decrease in ROM about 4 to 8 weeks after surgery. Radiographic examination re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2014