Chromogenic media vs real-time PCR for nasal surveillance of methicillin-resistant Staphylococcus aureus: impact on detection of MRSA-positive persons.

نویسندگان

  • Suzanne M Paule
  • Maitry Mehta
  • Donna M Hacek
  • Toni-Marie Gonzalzles
  • Ari Robicsek
  • Lance R Peterson
چکیده

Surveillance for methicillin-resistant Staphylococcus aureus (MRSA) colonization can be an important element for infection control programs when managing a multidrug-resistant pathogen such as MRSA. The sensitivity and speed of laboratory testing affects the proportion of appropriate isolation days captured, which determines the success or failure of a MRSA control program. Chromogenic culture, CHROMagar MRSA (BBL, Becton Dickinson, Sparks, MD) and MRSASelect (Bio-Rad, Hercules, CA), with and without broth enrichment and real-time polymerase chain reaction (PCR; BD GeneOhm MRSA, BD Diagnostics, San Diego, CA), were compared and found to have a wide range of sensitivities (78.5%-98.2%), specificities (91.6%-100.0%), and turnaround times (2-72 hours). Real-time PCR provided the most rapid results and demonstrated the highest sensitivity followed by broth-enriched culture and then direct plating for MRSA detection in nasal swabs. There was no substantial difference in the labor required for any of the 3 approaches.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) PCR versus the CHROMagar MRSA assay for screening patients for the presence of MRSA strains.

We compared the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) real-time PCR assay with the CHROMagar MRSA assay for the detection of MRSA in 286 nasal surveillance specimens. Compared with the CHROMagar MRSA assay, PCR had sensitivity, specificity, positive predictive value, and negative predictive values of 100%, 98.6%, 95.8%, and 100%, respectively. The mean PCR turnaround tim...

متن کامل

Comparative Evaluation of Three Chromogenic Media Combined with Broth Enrichment and the Real-Time PCR-Based Xpert MRSA Assay for Screening of Methicillin-Resistant Staphylococcus aureus in Nasal Swabs

BACKGROUND We evaluated the performance of three chromogenic media (Brilliance agar I [Oxoid, UK], Brilliance agar II [Oxoid], and ChromID MRSA [Biomérieux, France]) combined with broth enrichment and the Xpert MRSA assay for screening of methicillin-resistant Staphylococcus aureus (MRSA). METHODS We obtained 401 pairs of duplicate nasal swabs from 321 patients. One swab was suspended overnig...

متن کامل

Detection of Methicillin Resistant Staphylococcus aureus (MRSA) by CHROMagar Versus Cefoxitin Disk Diffusion Method

 Methicillin resistant Staphylococcus aureus (MRSA) has been emerged as a nosocomial and community acquired pathogen worldwide. There are many challenges for laboratory detection of MRSA. The aim of this study was to compare different phenotypic methods with PCR based method as a gold standard for detection of mecA gene to detection of MRSA. A total of 220 clinical isolates of S. aureus which w...

متن کامل

Frequency of nasal carriage for methicillin-resistant staphylococcus aureus among the hospital staff – Bandar Abbas, Iran

Introduction: Methicillin – resistant S.aureus (MRSA) hss been recognized as an important pathogen in human diseases. Screening of health care workers allowed early detection of nasal carriage of MRSA and prevention of subsequent transmission. The aim of this study was to determine the frequency of nasal carriage of MRSA in Shariati hospital staff. Methods: This cross – sectional study wa...

متن کامل

Evaluation of Different Phenotypic and Genotypic Methods for Detection of Methicillin Resistant Staphylococcus aureus (MRSA)

Background: Methicillin resistant Staphylococcus aureus (MRSA) has been emerged as a nosocomial and community acquired pathogen worldwide. There are many challenges for laboratory detection of MRSA. The aim of this study was to compare different phenotypic methods with PCR based method as a gold standard for detection of mecA gene. <b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 131 4  شماره 

صفحات  -

تاریخ انتشار 2009