Transcranial color-coded duplex sonography for detection of distal internal carotid artery stenosis.

نویسندگان

  • J Valaikiene
  • G Schuierer
  • B Ziemus
  • J Dietrich
  • U Bogdahn
  • F Schlachetzki
چکیده

BACKGROUND AND PURPOSE Gradation of high-grade intracranial internal carotid artery (ICA) stenosis poses a challenge to noninvasive neurovascular imaging, which seems critical for angioplasty in the ICA segments C1 and C5. We investigated cutoff values of intracranial ICA stenosis for transcranial color-coded sonography (TCCS) and compared this method with the "gold standard," digital subtraction angiography (DSA). MATERIALS AND METHODS Forty patients (mean age, 58.9 +/- 13.8 years) with intracranial ICA lesions were prospectively examined by using TCCS and DSA. Two standard TCCS coronal imaging planes were used to evaluate the intracranial ICA. In addition, a control group of 128 volunteers without cerebrovascular disease (mean age, 48.8 +/- 15.9 years) was investigated to establish standard velocity values. RESULTS DSA confirmed 96 stenoses and 8 occlusions of the intracranial ICA in the study population. In 9% and 7% of cases, stenosis confined to the C1 or C5 segment was >50% and 70%, respectively. Receiver-operating curves demonstrated cutoff values for >70% stenosis in C1 when the peak systolic velocity (PSV) was >200 cm/s (specificity, 100%; sensitivity, 71%) or the C1/submandibular ICA index was >3 (specificity, 93%; sensitivity, 86%). CONCLUSIONS TCCS is a reliable adjunctive method to detect and quantify significant stenosis of the intracranial ICA. The assessment of the C1/ICA index and peak systolic velocities maximizes the diagnostic accuracy of C1 stenosis to >70% when extracranial ICA stenosis coexists. Further studies need to be performed to compare the diagnostic accuracies of MR angiography and TCCS with that of DSA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduced Internal Carotid Artery Flow in Color-coded Carotid Duplex Sonography.

PURPOSE Reduced flow in the internal carotid artery (ICA) is related to cerebral ischemia. We established a classification of reduced ICA flow through color-coded carotid duplex (CCD) sonography. METHODS We retrospectively reviewed 25,000 CCD images in sonography laboratory. RESULTS Reduced ICA flow [flow volume (FV) less than 100 mL/min] was found in 1.2% of all studies, and 270 patients w...

متن کامل

Assessment of >/=50% and <50% intracranial stenoses by transcranial color-coded duplex sonography.

BACKGROUND AND PURPOSE A favorable risk-benefit ratio for warfarin compared with aspirin has been reported for the prevention of major vascular events in symptomatic >/=50% intracranial stenoses. Transcranial color-coded duplex sonography (TCCS) criteria providing an accurate detection of >/=50% and <50% stenoses of the anterior, middle, and posterior cerebral arteries and basilar and vertebral...

متن کامل

Benefit of echocontrast-enhanced transcranial color-coded duplex ultrasound in the assessment of intracranial collateral pathways.

BACKGROUND AND PURPOSE Although clinically important, proper assessment of intracranial arterial collateral pathways by transcranial color-coded duplex sonography (TCCD) in patients with internal carotid artery (ICA) high-grade stenosis or occlusion is occasionally made difficult by an insufficient temporal bone window, an unfavorable insonation angle, or low flow velocity or volume. In these c...

متن کامل

Echocontrast-enhanced ultrasound of extracranial internal carotid artery high-grade stenosis and occlusion.

BACKGROUND AND PURPOSE Proper assessment of extracranial internal carotid artery high-grade stenosis and occlusion by extracranial color-coded duplex sonography (ECCD) is occasionally made difficult by shadowing, an unfavorable insonation angle, low flow velocity or volume, or a deep insonation depth. In these cases, echocontrast could be helpful to quantify the degree of stenosis and to diagno...

متن کامل

Transcranial color-coded duplex sonography in unilateral flow-restrictive extracranial carotid artery disease.

PURPOSE To provide transcranial color-coded duplex flow-velocity data for the basal cerebral arteries in patients with unilateral flow-restrictive extracranial carotid artery disease, and to compare these data with the flow velocities obtained in healthy control subjects. METHODS Transcranial color-coded duplex sonography was performed in 78 patients with different patterns of cross flow thro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 29 2  شماره 

صفحات  -

تاریخ انتشار 2008