Intra-Arterial Fluorescence Angiography with Injection of Fluorescein Sodium from the Superficial Temporal Artery during Aneurysm Surgery: Technical Notes
نویسندگان
چکیده
Intra-arterial fluorescence angiography from a catheter inserted into the external carotid artery (ECA) via the superficial temporal artery (STA) allowed us to satisfactorily evaluate cerebral arterial and venous blood flow. We report this novel method that allowed for repeated angiography within minutes with a low risk of complications due to catheter placement from the STA. The STA was secured at the edge of the standard skin incision during cerebral aneurysm surgery. A 3 Fr catheter was inserted approximately 5 cm to 10 cm into the STA. After manual injection of 5 ml of 20 times diluted 10% fluorescein sodium (fluorescein), fluorescein reached the intracranial internal carotid artery (ICA) through the common carotid artery or anastomoses between the ECA and ICA. Fluorescence emission from the cerebral arteries, capillaries, and veins was clearly observed through the microscope and results were recorded. Quick dye clearance makes it possible to reexamine within 1 minute. In addition, we made a graph of the fluorescence emission intensity in the arteries, capillaries, and veins using fluorescence analysis software. With intravenous fluorescence angiography, dye remains in the vessels for a long time. When repeated examinations are necessary, intervals of approximately 10 minutes are required. There were some cases we could not correctly evaluate with intravenous injection due to weak fluorescence emission. Fluorescence angiography with intra-arterial injection from a catheter inserted into the carotid artery or another major vessel, like conventional angiography, has a risk of procedure-related complications. We report our new method since it solved these problems and is useful.
منابع مشابه
Development of and Clinical Experience with a Simple Device for Performing Intraoperative Fluorescein Fluorescence Cerebral Angiography: Technical Notes
To perform intraoperative fluorescence angiography (FAG) under a microscope without an integrated FAG function with reasonable cost and sufficient quality for evaluation, we made a small and easy to use device for fluorescein FAG (FAG filter). We investigated the practical use of this FAG filter during aneurysm surgery, revascularization surgery, and brain tumor surgery. The FAG filter consists...
متن کاملFluorescein angiography in microvascular surgery: a study using the rodent artery.
Fluorescein A ngiography in Microvascular Surgery: A Sniily ' Using the Rodent Artery • Fluorescein angiography was carried out on 45 Ostpon Mendelson rats with a view toward detecting injury areas following microvascular anastomoses. Decreased fluorescence was seen regardless if the injury occurred prior to or after the injection of fluorescein, and also if postinjury angiography was filmed du...
متن کاملAdvantage of Microscope Integrated for Both Indocyanine Green and Fluorescein Videoangiography on Aneurysmal Surgery: Case Report
Neck clipping of a large middle cerebral artery aneurysm was performed using a newly developed surgical microscope integrated with modules for both indocyanine green (ICG) and fluorescein videoangiography. During surgery, ICG and fluorescein videoangiography by intra-arterial or intravenous injection were safely carried out without interrupting the surgical procedure. Based on the findings obta...
متن کاملIntra-arterial injection of indocyanine green in cerebral arteriovenous malformation surgery.
Surgical microscope-integrated intraoperative angiography with intra-venous injection of indocyanine green (ICG) has been widely used during bypass or aneurysm surgery. Instead of intra-venous injection of ICG, we describe a case of intraoperative video angiography with intra-arterial injection of ICG in cerebral arteriovenous malformation (AVM) surgery. During the surgery, we injected ICG thro...
متن کاملSuperficial temporal artery to middle cerebral artery anastomosis. Intraoperative evaluation by fluorescein angiography and xenon-133 clearance.
Fluorescein angiography and xenon-133 (133Xe) clearance studies were performed during surgery on 15 patients who were undergoing superficial temporal artery (STA) to middle cerebral artery (MCA) anastomosis. Fourteen patients had occlusive disease of the internal carotid artery (ICA), and one patient had severe stenosis of the MCA. Before anastomosis, fluorescein angiography showed slow filling...
متن کامل