Effect of Advancing Age and Multiple Chronic Conditions on Mortality in Patients with End-Stage Renal Disease after Implantable Cardioverter-Defibrillator Placement.

نویسندگان

  • Ashok Krishnaswami
  • Mary-Lou Kiley
  • Faith F Anthony
  • Yuexin Chen
  • Jason Chen
  • Sumanth Rajagopal
  • Taylor I Liu
  • Charlie Young
  • Elizabeth W Paxton
چکیده

CONTEXT There is insufficient information on the effect that advancing age and multiple chronic conditions (MCC) have on mortality after placement of an implantable cardioverter-defibrillator in patients with end-stage renal disease (ESRD) vs non-ESRD. OBJECTIVE To assess whether a differential effect of age and MCC exists between ESRD and non-ESRD. DESIGN Population-based, retrospective cohort study using data from the national Kaiser Permanente Cardiac Device Registry of patients who underwent placement of an implantable cardioverter-defibrillator between January 1, 2007, and December 31, 2013. MAIN OUTCOME MEASURES All-cause mortality. RESULTS Of 7825 patients with implantable cardioverter-defibrillator placement, ESRD-affected patients constituted 4.0% of the cohort (n = 311), were similar in age (p = 0.91), and presented with a larger comorbidity burden (3.3 ± 1.3 vs 2.4 ± 1.5, p < 0.001). The effect of advancing age (every 5 years) on mortality in the ESRD cohort (hazard ratio [HR] = 1.11, 95% confidence interval [CI] = 1.03-1.20) was less than in the non-ESRD cohort (HR = 1.28, 95% CI = 1.25-1.32). Similarly, the effect of each additional comorbidity in the ESRD cohort was less (HR = 1.04, 95% CI = 0.91-1.19) than in the non-ESRD group (HR = 1.20, 95% CI = 1.16-1.25). Lastly, ESRD was independently associated with a 3-fold greater hazard of mortality. CONCLUSIONS Advancing age and increasing number of MCC have a differential effect on mortality risk in patients with ESRD compared with their non-ESRD counterparts. Future studies should focus on assessment of nonlinear relationships of age, MCC, and naturally occurring clusters of MCC on mortality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

The effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)

Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Survival after primary prevention implantable cardioverter-defibrillator placement among patients with chronic kidney disease.

BACKGROUND Guidelines recommend that implantable cardioverter-defibrillator (ICD) candidates have an estimated longevity of ≥1 year. Longevity can be affected by chronic kidney disease (CKD). METHODS AND RESULTS Using the National Cardiovascular Data Registry ICD registry linked with the Social Security Death Master File, we assessed the rate of death after primary prevention ICD placement be...

متن کامل

A Meta-Analysis of Mortality in End-Stage Renal Disease Patients Receiving Implantable Cardioverter Defibrillators (ICDs)

Data on the effectiveness of implantable implantable cardioverter defibrillators (ICDs) with respect to reducing mortality in patients with chronic kidney disease (CKD) and end-stage renal disease (ESRD) are lacking. The purpose of this meta-analysis was to compare the mortality of patients with ESRD who have received and not received an ICD. A search was conducted on January 31, 2013 of Medlin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Permanente journal

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2016