Ex Vivo Estimation of Photoacoustic Imaging for Detecting Thyroid Microcalcifications
نویسندگان
چکیده
BACKGROUND The aim of this study was to evaluate the diagnostic utility of PAI at detecting thyroid microcalcifications at 700 nm laser wavelengths. METHODS This study included 36 resected samples in 18 patients. To evaluate the PA manifestation of microcalcifications in PAI, gray level histogram and co-occurrence matrix (COM) texture parameters were extracted from the 3 fixed ROI US and PA images, respectively, per sample. We compared the textural parameters obtained from specimen PAIs between samples with punctate microcalcifications on specimen radiography and those without microcalcifications. RESULTS On specimen US, the mean value (2748.4 ± 862.5) of samples with microcalcifications on specimen radiography was higher than that (1961.9 ± 780.2) of those without microcalcifications (P = 0.007). However, there were no significant differences in textural parameters obtained from specimen PAIs between samples with punctate microcalcifications on specimen radiography and those without when applying both the mean value of the three slices of thyroid specimens and the value of the thyroid specimen slice which had the highest value of the mean values in specimen US. CONCLUSION PAI did not show significant PA contrast on thyroid microcalcifications indicating that the experimental setup and protocols should be enhanced, e.g., method of complete blood rejection from ex vivo specimens, the multi-wavelength spectroscopic PA imaging method which can solely extract the PA signal from microcalcifications even with high spectral interferences, or PA imaging with narrower slice thickness using 2-dimensional array transducer, etc.
منابع مشابه
Photoacoustic Imaging of Breast Microcalcifications: A Preliminary Study with 8-Gauge Core-Biopsied Breast Specimens
BACKGROUND We presented the photoacoustic imaging (PAI) tool and to evaluate whether microcalcifications in breast tissue can be detected on photoacoustic (PA) images. METHODS We collected 21 cores containing microcalcifications (n = 11, microcalcification group) and none (n = 10, control group) in stereotactic or ultrasound (US) guided 8-gauge vacuum-assisted biopsies. Photoacoustic (PA) ima...
متن کاملLaser scanning laser diode photoacoustic microscopy system
The development of low-cost and fast photoacoustic microscopy systems enhances the clinical applicability of photoacoustic imaging systems. To this end, we present a laser scanning laser diode-based photoacoustic microscopy system. In this system, a 905 nm, 325 W maximum output peak power pulsed laser diode with 50 ns pulsewidth is utilized as the light source. A combination of aspheric and cyl...
متن کاملRaman spectroscopy: a real-time tool for identifying microcalcifications during stereotactic breast core needle biopsies
Microcalcifications are an early mammographic sign of breast cancer and a target for stereotactic breast needle biopsy. We present here a Raman spectroscopic tool for detecting microcalcifications in breast tissue based on their chemical composition. We collected ex vivo Raman spectra from 159 tissue sites in fresh stereotactic breast needle biopsies from 33 patients, including 54 normal sites,...
متن کاملThree-Dimensional Photoacoustic Endoscopic Imaging of the Rabbit Esophagus
We report photoacoustic and ultrasonic endoscopic images of two intact rabbit esophagi. To investigate the esophageal lumen structure and microvasculature, we performed in vivo and ex vivo imaging studies using a 3.8-mm diameter photoacoustic endoscope and correlated the images with histology. Several interesting anatomic structures were newly found in both the in vivo and ex vivo images, which...
متن کاملPhotoacoustic-based sO2 estimation through excised bovine prostate tissue with interstitial light delivery
Photoacoustic (PA) imaging is capable of probing blood oxygen saturation (sO2), which has been shown to correlate with tissue hypoxia, a promising cancer biomarker. However, wavelength-dependent local fluence changes can compromise sO2 estimation accuracy in tissue. This work investigates using PA imaging with interstitial irradiation and local fluence correction to assess precision and accurac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2014