Mercury sphygmomanometers should not be abandoned: An advisory statement from the Council for High Blood Pressure Research, American Heart Association.

نویسندگان

  • D W Jones
  • E D Frohlich
  • C M Grim
  • C E Grim
  • K A Taubert
چکیده

In healthcare institutions around this country and around the world, mercury sphygmomanometers are being removed.1 In many situations, the decision to replace the instruments is being made without significant input from involved clinicians or consideration of the health risks that will follow if they are replaced by less accurate devices. Blood pressure measurement is an important indicator of the current clinical condition of patients and a powerful predictor of future cardiovascular and overall health.2 Blood pressure measurement is often considered “routine” and is often performed by those with the least training. In many institutions, blood pressure measurement is a low priority, with less than ideal quality control related to equipment selection, equipment calibration and repair, and personnel training and performance. For more than a century, the mercury gravity sphygmomanometer has been the gold standard for indirect measurement of blood pressure. Indeed, the world primary standard for pressure measurement is a mercury manometer. It is a simple, gravity-based unit with easy calibration, infrequent need for repair, and it has been validated in many clinical circumstances against direct intra-arterial blood pressure measurement.3 In recent years, these mercury units have been replaced with aneroid instruments in many institutions and more recently with electronic manometers. Justifications for the replacement of mercury manometers have included concerns about the safety of mercury, concerns about regulations regarding the use of mercury in the workplace, and attempts to eliminate human error involved in the reading of measurements.4 An examination of the evidence around these concerns is necessary before clinicians contribute actively or passively to the replacement of these instruments. Are mercury manometers dangerous to use in hospital and other clinical settings? Accidental exposure to mercury from sphygmomanometers used in healthcare settings is extremely rare. It is true that there have been a few isolated instances of illness in children from mercury toxicity related to broken elemental mercury-containing instruments used in homes. Most of these occurrences have been related to broken glass thermometers.5 One detailed report has provided data suggesting that volatilized mercury, after spillage of mercury, produced reversible neurological symptoms.6 Nevertheless, modern mercury sphygmomanometers are available in models that prevent accidental spillage of mercury, which essentially eliminates the concern for this rare occurrence. Is the use of mercury manometers forbidden by regulation in the United States? No. Most regulations related to mercury deal with mercury compounds, such as those used in the manufacture of some automobile batteries. The use of mercury manometers is presently restricted in only a handful of countries.1 None of the healthcare regulatory agencies in the United States, governmental or voluntary, forbid the use of mercury manometers. However, reports of loss of hospital accreditation in the United States (for whatever reasons) have prompted widespread concern. Notwithstanding, mercury instruments are approved and are legal devices in this country, and we believe they should remain so. Are aneroid or electronic instruments a reliable substitute for mercury manometers? There are 2 crucial issues to consider here: validation and calibration. Although both aneroid and electronic instruments have some advantages of portability and ease of use, few of these instruments have had adequate validation. Still fewer of these instruments are calibrated regularly. To be sure, these instruments have a place in patient management, particularly with respect to their use as home monitoring devices. However, most of these instruments have not been adequately validated over a wide range of blood pressures, ages, and clinical conditions to warrant routine use in hospitals and outpatient settings.7 What is of critical importance is that most manufacturers of aneroid and electronic instruments recommend calibration against a mercury manometer every 6 months. However, few hospitals and clinics have a regular program of evaluation and calibration. Most of these instruments cannot be calibrated without return to the manufacturer.8 Can the use of electronic instruments eliminate human error in blood pressure determination? Certainly, a challenging aspect of human blood pressure determination with a mercury sphygmomanometer is the human error introduced with the hearing and recording of the Korotkoff sounds. Hearing impairment and digit preference are 2 major concerns. Electronic instruments do offer an advantage in this area but still leave ample room for other causes of human error in cuff size determination, placement of the cuff, etc. It The opinions expressed in this editorial are not necessarily those of the editor or of the American Heart Association. Correspondence to Daniel Jones, MD, Professor of Medicine, University of Mississippi Medical Center, Division of Hypertension, 2500 North State St, Jackson, MS 39216-4505. E-mail [email protected] (Hypertension. 2001;37:185-186.) © 2001 American Heart Association, Inc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response to the Advisory Statement from the Council for high blood pressure research of the American Heart Association advocating retention of mercury sphygmomanometers.

Response to the Advisory Statement From the Council for High Blood Pressure Research of the American Heart Association Advocating Retention of Mercury Sphygmomanometers To the Editor: The editorial entitled “Mercury Sphygmomanometers Should Not be Abandoned: An Advisory Statement From the Council for High Blood Pressure Research, American Heart Association”1 highlights an important issue, which...

متن کامل

Dynamic reactions induced by compression of an artery.

IN 1941 a committee of the American Heart Association made some new "Recommendations for Human Blood Pressure Determinations by Sphygmomanometers." The report opened with a general statement from which we quote in part, "It should be clearly recognized that arterial pressures cannot be measured with precision by means of sphygmomanometers. . . . Despite this, clinical blood pressure determinati...

متن کامل

Dynamic Reactions Induced by Compression of an Artery

IN 1941 a committee of the American Heart Association made some new "Recommendations for Human Blood Pressure Determinations by Sphygmomanometers." The report opened with a general statement from which we quote in part, "It should be clearly recognized that arterial pressures cannot be measured with precision by means of sphygmomanometers. . . . Despite this, clinical blood pressure determinati...

متن کامل

Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research.

Accurate measurement of blood pressure is essential to classify individuals, to ascertain blood pressure-related risk, and to guide management. The auscultatory technique with a trained observer and mercury sphygmomanometer continues to be the method of choice for measurement in the office, using the first and fifth phases of the Korotkoff sounds, including in pregnant women. The use of mercury...

متن کامل

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 2001