Inter- Line Dynamic Voltage Restore and Fault Current Limiter (IDVR-FCL)
نویسنده
چکیده
This paper proposes a novel combined device for fault current limiting and dynamic voltage restoring. It consists of a diode bridge superconducting fault current limiter and a dynamic voltage restorer, which both connected together via a common dc link. Interline FCL-DVR system is interlined between two different feeders that connected to a point of common coupling (PCC) in distribution network. The structure, control strategy and capability of this equipment are discussed in this paper. Effectiveness of proposed configuration is verified through simulation by PSCAD/EMTDC.
منابع مشابه
Series Resonance Based Fault Current Limiter with Controlling The Point of Common Coupling Voltage
This paper proposes a novel Fault Current Limiter (FCL) for the application on distribution networks to control voltage sags at the Point of Common Coupling (PCC) during faults. This new FCL is based on series resonance including resonance transformer and series capacitor. So, by proper design of the series resonance LC tank, the fault current is limited to an acceptable level. The FCL operatio...
متن کاملDynamic Breaking in Cage Induction Motor
In this paper, short circuit analysis, based on the electromagnetic transient program (EMTP), has been used to investigate the behavior of the DC reactor type FCL installed in an electrical distribution grid. System studies show that the DC reactor type FCL can not only limit the fault current to an acceptable value, but also can mitigate the voltage sag. A DC reactor type fault current limiter...
متن کاملPerformance Assessment of IPFC with IDVR for Two Feeder Transmission systems
The dynamic voltage restorer (DVR) is one of the modern devices used in transmission systems to protect power flow against sudden changes in voltage amplitude. The proposed algorithm is applied to some disturbances in load voltage caused by induction motors starting, and a three-phase short circuit fault. Also, the capability of the proposed DVR has been tested to limit the downstream fault cur...
متن کاملInfluence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملImpact of Bridge type Fault Current Limiter on Power System Transient Stability
In this paper, transient stability improvement using bridge type fault current limiter (FCL) is presented in single machine infinite bus (SMIB) system with a double circuit transmission line. Three single-phase sets of the proposed FCL are installed at the beginning of feeder. The proposed FCL inserts an inductance and a resistance in the fault current pass. The insertion inductance and resista...