Prospective multiaxial motion correction for fMRI.

نویسندگان

  • H A Ward
  • S J Riederer
  • R C Grimm
  • R L Ehman
  • J P Felmlee
  • C R Jack
چکیده

Corruption of the image time series due to interimage head motion limits the clinical utility of functional MRI. This paper presents a method for real-time prospective correction of rotation and translation in all six degrees of rigid body motion. By incorporating an orbital navigator (ONAV) echo for each of the sagittal, axial, and coronal planes into the fMRI pulse sequence, rotation and translation can be measured and the spatial orientation of the image acquisition sequence that follows can be corrected prospectively in as little as 160 msec. Testing of the method using a computerized motion phantom capable of performing complex multiaxial motion showed subdegree rotational and submillimeter translational accuracy over a range of +/-8 degrees and +/-8 mm of motion. In vivo images demonstrate correction of simultaneous through-plane and in-plane motion and improved detection of fMRI activation in the presence of head motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Towards combining prospective motion correction and distortion correction for EPI

Introduction: In most fMRI studies, subject motion is assumed to be restricted to such a small amount that susceptibility-induced distortions can be treated as stationary and independent from motion. However, the ultimate goal of this project is to enable fMRI studies during significant head motion by applying prospective motion correction techniques [1]. In this regime, the motion dependence o...

متن کامل

Real-Time Prospective Slice-by-Slice Motion Correction for fMRI in Freely Moving Subjects

INTRODUCTION Functional Magnetic Resonance Imaging (fMRI) is being used extensively in neuroscientific studies and is entering the clinical field. Due to its low inherent effect to noise ratio even at high field strength the results are often compromised by adverse events during the acquisition. The most frequent cause of signal fluctuations that degrade the detection of paradigm induced neuron...

متن کامل

Head pose prediction for prospectively-corrected EPI during rapid subject motion

INTRODUCTION Prospective motion correction using an external tracking device is an effective technique for motion correction in fMRI [1]. It has advantages over image-based correction methods [2], which require full volume coverage to compute motion parameters in a full six degrees of freedom (6DOF). The ultimate goal of this project is to use prospective correction to perform fMRI experiments ...

متن کامل

Prospective active marker motion correction improves statistical power in BOLD fMRI

Group level statistical maps of blood oxygenation level dependent (BOLD) signals acquired using functional magnetic resonance imaging (fMRI) have become a basic measurement for much of systems, cognitive and social neuroscience. A challenge in making inferences from these statistical maps is the noise and potential confounds that arise from the head motion that occurs within and between acquisi...

متن کامل

Hybrid Prospective & Retrospective Head Motion Correction System to Mitigate Cross-Calibration Errors

INTRODUCTION – Correction of head motion artifacts is essential for clinically acceptable image quality. This is especially important for long scans, such as DTI, fMRI, and high-resolution structural scans. Prospective motion-correction using stereovision systems [1,2] have been suggested to perform real-time head motion-correction without necessitating the acquisition of additional MR-based na...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 43 3  شماره 

صفحات  -

تاریخ انتشار 2000