New approach for diagnosis of candidemia based on detection of a 65-kilodalton antigen.

نویسندگان

  • Rodrigo Berzaghi
  • Arnaldo Lopes Colombo
  • Antonia Maria de Oliveira Machado
  • Zoilo Pires de Camargo
چکیده

Nosocomial candidiasis is a major concern in tertiary care hospitals worldwide. This infection generally occurs in patients with degenerative and neoplastic diseases and is considered the fourth most frequent cause of bloodstream infections. Diagnosis of candidemia or hematogenous candidiasis has been problematic because clinical signs and symptoms are nonspecific, leading to delays in diagnosis and, consequently, delays in appropriate antifungal therapy. We developed an inhibition enzyme-linked immunosorbent assay (ELISA) for detection of a 65-kDa antigen in an experimental model of candidemia and for diagnosis of patients in intensive care units (ICUs) with suspected candidemia. An anti-65-kDa monoclonal antibody was tested for detection of the 65-kDa antigen produced by Candida albicans, Candida tropicalis, and Candida parapsilosis in murine candidemia models. The 65-kDa antigen was detected in sera at concentrations ranging from 0.012 to 3.25 microg/ml. A total of 20 human patients with candidemia were then evaluated with the inhibition ELISA using sequential sera. Sixteen (80%) patients had the 65-kDa antigen in concentrations ranging from 0.07 to 5.0 microg/ml. Sequential sera from patients with candidemia presented three different patterns of antigenemia of the 65-kDa molecule: (i) total clearance of antigenemia, (ii) initial clearance and relapse of antigenemia, and (iii) partial clearance of antigenemia. Our results indicate detection of the 65-kDa protein may be a valuable tool for the diagnosis of candidemia by C. albicans, C. tropicalis, and C. parapsilosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Assessment of rEPC1 antigen and Copro-antigen for diagnosis of Echinococcosis in dogs

Abstract BACKGROUND: Diagnosis of Echinococcus granulosus in the definitive host particularly in dog is the significant complication in the endemic area. OBJECTIVES: The aim of this study is serological detection of E. granulosus in the infected dogs. METHODS: Dot-ELISA based on the copro-antigen and recombinant EPC1 antigen (rEPC1) for antibody detection was performed. Blood and fecal samples ...

متن کامل

A multiple-antigen detection assay for tuberculosis diagnosis based on broadly reactive polyclonal antibodies

Objective(s): Detection of circulating Mycobacterium tuberculosis (M. tuberculosis) antigens is promising in Tuberculosis (TB) diagnosis. However, not a single antigen marker has been found to be widely expressed in all TB patients. This study is aimed to prepare broadly reactive polyclonal antibodies targeting multiple antigen markers (multi-target antibodies) and evaluate their efficacies in ...

متن کامل

LEVELS OF ANTI-STREP TOKINASE AND ANTI-MYCOBACTERIAL HEAT SHOCK PROTEIN 65 KILODALTON (ANTI-MHSP 65) ANTIBODIES IN PATIENTS WITH AUTOIMMUNE DISEASES

Bacterial and viral triggers are suspected agents in the initial etiology of autoimmune diseases. There are some studies on the etiology of autoimmune disorders which have focused on streptococcal infection and a possible relation with microbial heat shock proteins (hsp) which show significant homology with human heat shock proteins. In addition, some serotypes of streptococci cross-react ...

متن کامل

A Capture ELISA for the Diagnosis of Visceral Leishmaniasis Using a Monoclonal Antibody against a Leishmanial

capture ELISA system was developed for diagnosis of visceral leishmaniasis (VL) using a monoclonal antibody raised against an antigen previously detected in the urine of VL patients. Urine samples from confirmed VL cases from Yemen, Nepal, Spain, Sudan and Brazil were tested in the capture ELISA in comparison with urine samples from endemic and non-endemic areas along with urine samples from pa...

متن کامل

Model-based Approach for Multi-sensor Fault Identification in Power Plant Gas Turbines

In this paper, ‎the multi-sensor fault diagnosis in the exhaust temperature sensors of a V94.2 heavy duty gas turbine is presented‎. ‎A Laguerre network-based fuzzy modeling approach is presented to predict the output temperature of the gas turbine for sensor fault diagnosis‎. Due to the nonlinear dynamics of the gas turbine, in these models the Laguerre filter parts are related to the linear d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical and vaccine immunology : CVI

دوره 16 11  شماره 

صفحات  -

تاریخ انتشار 2009