Determination of the taste threshold of copper in water.

نویسندگان

  • I Zacarías
  • C G Yáñez
  • M Araya
  • C Oraka
  • M Olivares
  • R Uauy
چکیده

Copper effects on human health represent a relevant issue in modern nutrition. One of the difficulties in assessing the early, acute effects of copper ingested via drinking water is that the taste of copper may influence the response and the capacity to taste copper in different waters is unknown. The purpose of the study was to determine the taste threshold of copper in different types of water, using soluble and insoluble salts (copper sulfate and copper chloride). Copper-containing solutions (range 1.0-8.0 mg/l Cu) were prepared in tap water, distilled deionized water and uncarbonated mineral water. Sixty-one healthy volunteers (17-50 years of age), with no previous training for sensory evaluation, participated in the study. A modified triangle test was used to define the taste threshold value. The threshold was defined as the lowest copper concentration detected by 50% of the subjects assessed. To evaluate the olfactory input in the threshold value obtained, 15 of 61 subjects underwent a second set of triangle tests with the nose open and clamped, using distilled water with copper sulfate at a concentration corresponding to the individual's threshold. The taste threshold in tap water was 2.6 mg/l Cu for both copper sulfate and copper chloride. The corresponding values for distilled deionized water were 2.4 and 2.5 mg/l Cu for copper sulfate and copper chloride, respectively. In uncarbonated mineral water the threshold values were slightly higher, 3.5 and 3.8 mg/l Cu for copper sulfate and for copper chloride, respectively, which are significantly higher than those observed in tap and distilled waters (P < 0.01, Kruskal-Wallis test). The taste threshold did not change significantly when the nose was clamped. In conclusion, the median values for copper taste threshold were low, ranging between 2.4 and 3.8 mg/l Cu, depending on the type of water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Voltammetric Determination of Copper Ion in Water Samples Using a Drop Casted Biopolymer

Poly-dopamine, inspired by biopolymers of mussels, is an adhesive catecholamine possessing low cytotoxicity and very good biocompatibility. In the present study, poly-dopamine nanoparticles (PDNP), as a biopolymer, were synthesized and characterized using FTIR spectroscopy, scanning electron microscopy and electrochemical methods. The drop casted PDNPs at the surface of carbon paste electrode (...

متن کامل

Ion Pair Dispersive Liquid-Liquid Microextraction for the Determination of Trace Amounts of Copper(II) in Soil, Multivitamin Tablet, Tea and Water Samples Using Flame Atomic Absorption Spectrometry

Ion pair dispersive liquid- liquid microextraction (IP-DLLME) method combined with flame atomic absorption spectrometry was proposed for the determination of trace amounts of copper(II). By using pyrocatechol violet as chelating agent and cetyltrimethyl ammonium bromide as an ion pairing agent, the trace amount of copper(II) was extracted in chloroform. The factors influencing the formation cop...

متن کامل

Extraction-Fluorimetric Determination of Low Levels of Copper by 1,7- Diaza-15-Crown-5 and Rose Bengal

A simple and sensitive extraction-fluorimetric method for the determination of copper is reported. The 1,7-diaza-15-crown-5-copper-rose Bengal (DA15C5-Cu-RB) ternary complex is quantitatively extracted into chloroform, diluted with ammoniacal acetone and its fluorescence intensity is measured at 570 nm with excitation at 540 nm. A linear calibration graph was obtained over the copper concen...

متن کامل

Extraction and Determination of Heavy Metals Using Silver Coated Magnetic Nanoparticles and Flame Atomic Absorption Spectrometry

A rapid, simple and sensitive magnetic solid phase extraction (MSPE) method was developed for the pre-concentration and determination of copper and cadmium ions. In this study, modified Fe3O4@Ag nanoparticles were synthesized and then ligand 2-isonicotinoyl hydrazine carbodithiolate (ITHCDT) was bonded to silver due to the formation of covalent bond of S-Ag. In this method, copper and cadmium i...

متن کامل

Taste and mouthfeel assessment of porous and non-porous silicon microparticles

Unlike the trace minerals iron, copper and zinc, the semiconductor silicon has not had its organoleptic properties assessed. Nanostructured silicon provides the nutrient orthosilicic acid through hydrolysis in the gastrointestinal tract and is a candidate for oral silicon supplements. Mesoporous silicon, a nanostructured material, is being assessed for both oral drug and nutrient delivery. Here...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical senses

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2001