Icodextrin instead of glucose during the daytime dwell in CCPD increases ultrafiltration and 24-h dialysate creatinine clearance.

نویسندگان

  • N Posthuma
  • P M ter Wee
  • H A Verbrugh
  • P L Oe
  • E Peers
  • J Sayers
  • A J Donker
چکیده

BACKGROUND AND METHODS Icodextrin 7.5% is an iso-osmolar, glucose polymer-containing peritoneal dialysis solution with an ultrafiltration potential similar to glucose 3.86%. We compared in an open, randomized, prospective study the ultrafiltration potential of icodextrin with that of glucose during the daytime dwell of 23 patients treated with automated peritoneal dialysis (CCPD). RESULTS Daytime ultrafiltration volume and 24-h ultrafiltration volume increased significantly in icodextrin-treated patients (n = 11) at 3 and 6 months, allowing patients a less rigid fluid restriction or an adapted treatment schedule. This improved the patients' subjective well-being. Although ultrafiltration at 9 and 12 months also increased it did not reach statistical significance. Similar to the gain in ultrafiltration volume, 24-h dialysate creatinine clearance per 1.73 m2 (DCl/1.73 m2) and DCl/1.73 m2 per litre used dialysate (DCl/1.73 m2/l) increased in icodextrin-treated patients. DCl/1.73 m2/l per litre ultrafiltrate (DCl/1.73 m2/l/UF) did not increase. No side-effects of icodextrin were encountered, although serum disaccharide levels increased. CONCLUSION Icodextrin enhances ultrafiltration during the daytime dwell in CCPD patients. As a result of an increased 24-h ultrafiltration volume, DCl/1.73 m2 and DCl/1.73 m2/l improve. DCl/1.73 m2/l/UF does not rise, which suggests that the increase in DCl/1.73 m2 and DCl/1.73 m2/l is caused by convective transport.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of icodextrin and glucose solutions for the daytime dwell in automated peritoneal dialysis.

BACKGROUND The sustained ultrafiltration achieved by icodextrin is more suited for the daytime dwell in automated peritoneal dialysis (APD) than glucose solutions. METHODS Seventeen patients receiving APD underwent assessment using three different solutions for the daytime dwell: 2.27% glucose, 3.86% glucose and 7.5% icodextrin. Patients were then observed on icodextrin for a 6 month period. ...

متن کامل

Long daytime exchange in children on continuous cycling peritoneal dialysis: preservation of drained volume because of icodextrin use.

Daytime exchanges with glucose osmotic agents often lead to dialysate reabsorption, poor ultrafiltration (UF), positive sodium balance, and restricted purification of uremic toxins. We studied 5 anuric children on continuous cycling peritoneal dialysis (mean age: 10 years, 10 months), comparing icodextrin to a conventional glucose-based dialysate. The same fill volume (980 +/- 290 mL/m2) and th...

متن کامل

Amadori albumin and advanced glycation end-product formation in peritoneal dialysis using icodextrin.

OBJECTIVE To study the influence of peritoneal dialysis (PD) solutions on the formation of early glycated products and advanced glycation end-products (AGEs). DESIGN AND PATIENTS The formation of both Amadori albumin and AGEs in glucose- and icodextrin-based PD fluids was analyzed in vitro and in peritoneal effluents of continuous cyclic peritoneal dialysis (CCPD) patients. RESULTS Albumin ...

متن کامل

Sodium removal in peritoneal dialysis: the role of icodextrin and peritoneal dialysis modalities.

One of the main goals of dialysis is the control of extracellular volume, because inadequate sodium and fluid removal result in fluid overload and increased mortality. In the present study, we evaluated the roles of continuous ambulatory peritoneal dialysis (CAPD), continuous cycling peritoneal dialysis (CCPD), and the use of icodextrin on sodium removal in 29 patients (n = 18 on CAPD, n = 11 o...

متن کامل

Superiority of icodextrin compared with 4.25% dextrose for peritoneal ultrafiltration.

Several clinical observations suggest the superiority of icodextrin compared with 4.25% dextrose in optimizing peritoneal ultrafiltration (UF), but no rigorous controlled evaluation has hitherto been performed. For comparing icodextrin and 4.25% dextrose during the long dwell of automated peritoneal dialysis, a multicenter, randomized, double-blind trial was conducted in 92 patients (control, 4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 12 3  شماره 

صفحات  -

تاریخ انتشار 1997