Reducing the time period of steady state does not affect the accuracy of energy expenditure measurements by indirect calorimetry.

نویسندگان

  • Marina M Reeves
  • Peter S W Davies
  • Judith Bauer
  • Diana Battistutta
چکیده

Achievement of steady state during indirect calorimetry measurements of resting energy expenditure (REE) is necessary to reduce error and ensure accuracy in the measurement. Steady state is often defined as 5 consecutive min (5-min SS) during which oxygen consumption and carbon dioxide production vary by +/-10%. These criteria, however, are stringent and often difficult to satisfy. This study aimed to assess whether reducing the time period for steady state (4-min SS or 3-min SS) produced measurements of REE that were significantly different from 5-min SS. REE was measured with the use of open-circuit indirect calorimetry in 39 subjects, of whom only 21 (54%) met the 5-min SS criteria. In these 21 subjects, median biases in REE between 5-min SS and 4-min SS and between 5-min SS and 3-min SS were 0.1 and 0.01%, respectively. For individuals, 4-min SS measured REE within a clinically acceptable range of +/-2% of 5-min SS, whereas 3-min SS measured REE within a range of -2-3% of 5-min SS. Harris-Benedict prediction equations estimated REE for individuals within +/-20-30% of 5-min SS. Reducing the time period of steady state to 4 min produced measurements of REE for individuals that were within clinically acceptable, predetermined limits. The limits of agreement for 3-min SS fell outside the predefined limits of +/-2%; however, both 4-min SS and 3-min SS criteria greatly increased the proportion of subjects who satisfied steady state within smaller limits than would be achieved if relying on prediction equations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Approximate Time to Steady-state Resting Energy Expenditure Using Indirect Calorimetry in Young, Healthy Adults

Indirect calorimetry (IC) measurements to estimate resting energy expenditure (REE) necessitate a stable measurement period or steady state (SS). There is limited evidence when assessing the time to reach SS in young, healthy adults. The aims of this prospective study are to determine the approximate time to necessary reach SS using open-circuit IC and to establish the appropriate duration of S...

متن کامل

Erratum to: Can calculation of energy expenditure based on CO2 measurements replace indirect calorimetry?

BACKGROUND Methods to calculate energy expenditure (EE) based on CO2 measurements (EEVCO2) have been proposed as a surrogate to indirect calorimetry. This study aimed at evaluating whether EEVCO2 could be considered as an alternative to EE measured by indirect calorimetry. METHODS Indirect calorimetry measurements conducted for clinical purposes on 278 mechanically ventilated ICU patients wer...

متن کامل

Predictive equations for energy needs for the critically ill.

Nutrition may affect clinical outcomes in critically ill patients, and providing either more or fewer calories than the patient needs can adversely affect outcomes. Calorie need fluctuates substantially over the course of critical illness, and nutrition delivery is often influenced by: the risk of refeeding syndrome; a hypocaloric feeding regimen; lack of feeding access; intolerance of feeding;...

متن کامل

Cumulative energy imbalance in the pediatric intensive care unit: role of targeted indirect calorimetry.

INTRODUCTION Failure to accurately estimate energy requirements may result in underfeeding or overfeeding. In this study, a dedicated multidisciplinary nutrition team measured energy expenditure in critically ill children. METHODS Steady-state indirect calorimetry was used to obtain measured resting energy expenditure, which was compared with equation-estimated energy expenditure and the tota...

متن کامل

Measured energy expenditure of tube-fed patients with severe neurodevelopmental disabilities.

OBJECTIVE To determine measured resting energy expenditure (REE) of nonambulatory tube-fed patients with severe neurological neurodevelopmental disabilities. METHODS Twenty patients were prospectively studied. Only steady state indirect calorimetry measurements were taken. All measurements were conducted using a canopy system. Nutritional needs were met entirely by enteral feedings via a perm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 97 1  شماره 

صفحات  -

تاریخ انتشار 2004