Reliability and sensitivity of the TonoLab rebound tonometer in awake Brown Norway rats.
نویسندگان
چکیده
PURPOSE To compare the sensitivity of the TonoLab rebound tonometer with the Tono-Pen in awake Brown Norway rats and to compare their ability to predict optic nerve damage induced by experimental IOP elevation. METHODS TonoLab and Tono-Pen tonometers were calibrated in cannulated rat eyes connected to a pressure transducer. The TonoLab was used in awake animals housed in standard lighting to measure IOP during light and dark phases. Both instruments were used to monitor chronically elevated IOP produced by episcleral vein injection of hypertonic saline. Measured IOPs were correlated with quantified optic nerve damage in injected eyes. RESULTS Although they were lower than transducer and Tono-Pen measurements at all levels, TonoLab readings showed an excellent linear fit with transducer readings from 20 to 80 mm Hg (R(2) = 0.99) in cannulated eyes. In awake animals housed in standard lighting, the TonoLab documented significantly higher pressures during the dark phase (27.9 +/- 1.7 mm Hg) than during the light phase (16.7 +/- 2.3 mm Hg). With elevated IOP, correlation between TonoLab and Tono-Pen readings (R(2) = 0.86, P < 0.0001) was similar to that in cannulated eyes. Although both instruments provided measurements that correlated well with optic nerve injury grade, only the Tono-Pen documented significant IOP elevation in eyes with the least amount of injury (P < 0.05). CONCLUSIONS The TonoLab is sensitive enough to be used in awake Brown Norway rats, though instrument fluctuation may limit its ability to identify significant pressure elevations in eyes with minimal optic nerve damage.
منابع مشابه
Noninvasive measurement of rodent intraocular pressure with a rebound tonometer.
PURPOSE The present study evaluated the applicability of a rebound tonometer in measuring intraocular pressure (IOP) in rats and mice. METHODS The accuracy of the TonoLab rebound tonometer was determined in cannulated mouse and rat eyes. IOP was manipulated by changing reservoir height, and tonometer pressure readings were recorded by an independent observer. IOP values were recorded in consc...
متن کاملATP-sensitive potassium (KATP) channel activation decreases intraocular pressure in the anterior chamber of the eye.
PURPOSE. ATP-sensitive potassium channel (K(ATP)) openers target key cellular events, many of which have been implicated in glaucoma. The authors sought to determine whether K(ATP) channel openers influence outflow facility in human anterior segment culture and intraocular pressure (IOP) in vivo. METHODS. Anterior segments from human eyes were placed in perfusion organ culture and treated with ...
متن کاملDiagnostic accuracy of the iCare rebound tonometer compared to the Perkins applanation tonometer in assessing intraocular pressure in rural patients.
BACKGROUND Vision health is recognized as a critical unmet need in North America. The ocular morbidity associated with glaucoma results from increased intraocular pressure (IOP) and early detection is crucial for the management of glaucoma. Our objective was to find a diagnostically accurate screening tool for intraocular hypertension that can be used in rural communities. We sought to validate...
متن کاملPreservation of retina ganglion cell function by morphine in a chronic ocular-hypertensive rat model.
PURPOSE The current study examined if opioid-receptor-activation by morphine can improve retinal function and retinal ganglion cell (RGC) integrity in a chronic glaucoma rat model. METHODS IOP was raised in Brown Norway rats by injecting hypertonic saline into the limbal venous system. Rats were treated daily with 1 mg/kg morphine for 28 days at 24-hour intervals; animals were examined for ch...
متن کاملReproducibility and clinical evaluation of rebound tonometry.
PURPOSE To establish the reproducibility of a rebound tonometer in humans and the effect of corneal thickness on measurements, comparing it with Goldmann applanation tonometer. METHODS In a first study designed to examine the reliability of the RBT, three experienced ophthalmologists undertook three consecutive intraocular pressure (IOP) measurements in 12 eyes of 12 normal subjects. A cross-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 50 6 شماره
صفحات -
تاریخ انتشار 2009