Analysis of glistenings in hydrophobic acrylic intraocular lenses on visual performance.
نویسندگان
چکیده
AIM To assess patients' visual performance with glistenings in one piece soft hydrophobic acrylic intraocular lenses (IOLs) (Alcon) 2 years postoperatively. METHODS This cross section trial included 120 eyes with one piece IOL at 2 years postoperatively. Glistening was classified in 4 groups, ranging from 0 (none) to 3 (most evident) according to their severity in IOLs optics observed under a slit lamp. All eyes underwent a uncorrected and best-corrected visual acuity evaluation (UCVA and BCVA, LogMAR scale), a complete clinical examination, a contrast sensitivity (CS) evaluation by F.A.C.T chart, and a visual field test by Humphrey Field Analyzer ‖ (HFA). One-way ANOVA was used for quantitative data, while Pearson χ (2) test was used for qualitative data to analyze the visual function of 4 glistening groups. RESULTS Totally 120 eyes were enrolled with 30 eyes in each glistening group. There was no statistical correlation between glistening grades and patients' age, IOLs power, postoperative UCVA and BCVA (P>0.05). Quantificationally, CS values among each group were not statistically different. However, qualitative analysis showed there were more eyes in grade 3 group than in grade 0 group having abnormally declined CS at high spatial frequency (10% vs 36.7% at 18 cpd, P=0.029; 6.7% vs 26.7% at 12 cpd, P=0.013). Mean deviation (MD) of the visual field test was -2.14±2.31, -1.97±2.23, -3.02±3.17, -4.12±3.38 in group 0 to 3 respectively. There was a significant decrease in the most serious glistenings group (P =0.018). CONCLUSION Glistenings may potentially have an impact on contrast sensitivity at high spatial frequency and MD in visual field test.
منابع مشابه
Evaluation of in vitro glistening formation in hydrophobic acrylic intraocular lenses
PURPOSE To evaluate the impact of continuous manufacturing process improvements on glistening formation in AcrySof hydrophobic acrylic intraocular lenses (IOLs) by comparing lenses manufactured in 2003 with lenses manufactured in 2012. METHODS Glistenings were experimentally created as aqueous-filled microvacuoles utilizing an accelerated laboratory method by immersing the lens in water at 45...
متن کاملGlistenings in hydrophobic acrylic intraocular lenses do affect visual function
(unported, v3.0) License. The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. Permissions beyond the scope of the License are administered by Dove Medical Press Limited. Information on how to request pe...
متن کاملAssessment of new-generation glistening-free hydrophobic acrylic intraocular lens material.
PURPOSE To determine the hydrophobic, antiglistening, and bioadhesiveness properties of a new polymer, GF raw material, and to determine the suitability of this material for use in intraocular lenses (IOLs). SETTING University of Liege, Liege, Belgium. DESIGN Experimental study. METHODS Intraocular lenses made of the new hydrophobic acrylic material were tested and compared with reference...
متن کاملA comparison of mesopic visual acuity and objective visual quality following cataract surgery with hydrophobic acrylic intraocular lenses
PURPOSE To evaluate mesopic visual acuity and visual quality as measured by objective scatter index (OSI) in pseudophakic eyes with long-term follow-up after implantation of hydrophobic acrylic lenses made from two different lens materials. SETTING This study was carried out in a private clinic. DESIGN This study was an observational cohort study. METHODS This pilot study included 181 eye...
متن کاملLong-Term Stability of Diffractive Multifocal Intraocular Lenses: Contralateral Comparison between Silicone and Acrylic Materials
Objective: To compare visual function stability between silicone and hydrophobic acrylic materials of diffractive multifocal intraocular lenses (MF-IOLs). Methods: This retrospective study reviewed clinical records of 10 patients who received a silicone MF-IOL in the first eye and hydrophobic acrylic lens in the fellow eye. Intra-individual differences in logMAR corrected distance visual acuity...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of ophthalmology
دوره 7 3 شماره
صفحات -
تاریخ انتشار 2014