Heat Transfer Coefficient, Two-Phase Flow Boiling of HFC134a
نویسنده
چکیده
Experimental measurements of local heat tra nsfer coefficients and pressure drop are made for forced conv ection boiling and condensation for R134a-oil mixtures inside a horizontal tube. The results are compared with the experime ntal data of pure Rl34a. Average convection boiling and cond ensation heat transfer coefficients decreased about 20% at a 10\ o il mass fraction, and boiling and condensation pressure drop were 2. 5 and 1.4 times that of pure refrigerant flow respectively. INTRODUCTION Rl34a is most likely to be an alternative r efrigerant for Rl2 which is used as a refrigerant in automotiv e air conditioners and domestic refrigerators. Therefore, the heat transfer coefficient and in-tube pressure drop for Rl34a are desired in designing new systems that use Rl34a as the working fluid. Espec ially, the influence of oil on the heat transfer coefficient and th e pressure drop in heat exchangers have to be estimated, because lu bricants always circulate in actual vapor compression refrigeration s ystems. Eckels and Pate (1990) estimated the heat t ransfer coefficients , for R134a by using reliable correlations, a nd compared them to the heat transfer coefficients for R12. However . they did not take into account the oil effect on the heat transfer coefficients. An experimental study of the heat transfer coefficients and pressure drop for forced convection boiling and condensation of R134a-oil mixtures inside a horizontal tube are described in this paper. The results are compared with the ex perimental data for a R12oil mixture. FORCED CONVECTION BOILING HEAT TRANSFER COE FFICIENTS AND PRESSURE DROP Experimental Apparatus A schematic diagram of the apparatus is sho wn in Figure 1. This apparatus consists of a refrigeration cycle and an oil circulating loop. The main components of the refrigerat ion cycle are a hermetic compressor, oil separator, condenser, expan sion valve, test section and an evaporator. The oil is eliminated fr om the compressor discharge gas by the oil separator. The ref rigerant mass flow rates are controlled by using the expansion valve , and are measured with a turbine-type flow meter. The oil contained in the compressor shell i s taken out from the compressor shell bottom, and transferred to the test section inlet by a gear-type oil pump. The oil mass flow rates are changed by controlling the oil pump rotating speed. an d are measured with a oil flow meter. The refrigerant-oil mixtures flow into the test section where the heat transfer coefficients and pressure drop are measured. The
منابع مشابه
Two Phase Flow Simulation for Subcooled Nucleat Boiling Heat Transfer Calculation in Water Jacket of Diesel Engine
Basic understanding of the process of coolant heat transfer inside an engine is an indispensable prerequisite to devise an infallible cooling strategy. Coolant flow and its heat transfer affect the cooling efficiency, thermal load of heated components, and thermal efficiency of a diesel engine. An efficient approach to studying cooling system for diesel engine is a 3D computational fluid dynami...
متن کاملExperimental Investigation of Boiling and Condensation Heat Transfer of a two Phase Closed Thermosyphon
In this paper the heat transfer characteristics of a two-phase closed thermosyphon over a wide range of heat transfer rates, system pressure, aspect ratios and filling ratios were studied. The experiments focused on the boiling and condensation heat transfer characteristics of the thermosyphon. The experimental boiling and condensation heat transfer coefficients inside the thermosyphon were com...
متن کاملExperimental Investigation of Boiling and Condensation Heat Transfer of a Two Phase Closed Thermosyphon
In this paper the heat transfer characteristics of a two-phase closed thermosyphon over a wide range of heat transfer rates, system pressure, aspect ratios and filling ratios were studied. The experiments focused on the boiling and condensation heat transfer characteristics of a thermosyphon with a copper tube having 25 and 32 mm inside and outside diameters. Distilled water was used as the wor...
متن کاملTwo Phase Heat Transfer Characteristics in a Vertical Small Diameter Tube at Sub Atmospheric Pressure
Two-phase heat transfer is experimentally examined through vertical small diameter tubes, D =1.45 and 2.8 mm using water under a pressure of 50 to 81 kPa and a natural circulation condition. The pool boiling correlation by Stephan-Abdelsalam and the thermosyphon boiling correlation by Imura, et al. predict the measured experimental data in the 2.8 mm tube with an error of -30%. A large heat tra...
متن کاملFlow boiling heat transfer in two-phase micro-channel heat sinks––II. Annular two-phase flow model
This paper is Part II of a two-part study devoted to measurement and prediction of the saturated flow boiling heat transfer coefficient in water-cooled micro-channel heat sinks. Part I discussed the experimental findings from the study, and identified unique aspects of flow boiling in micro-channels such as abrupt transition to the annular flow regime near the point of zero thermodynamic equili...
متن کاملSimulation of Boiling in a Vertical Channel Using Ensemble Average Model
Simulation of turbulence boiling, generation of vapour and predication of its behaviour are still subject to debate in the two-phase flow area and they receive a high level of worldwide attention. In this study, a new arrangement of the three dimensional governing equations for turbulence two-phase flow with heat and mass transfer are derived by using ensemble averaging two-fluid model and ...