Direct monitoring of coronary artery motion with cardiac fat navigator echoes.
نویسندگان
چکیده
Navigator echoes (NAVs) provide an effective means of monitoring physiological motion in magnetic resonance imaging (MRI). Motion artifacts can be suppressed by adjusting the data acquisition accordingly. The standard pencil-beam NAV has been used to detect diaphragm motion; however, it does not monitor cardiac motion effectively. Here we report a navigator approach that directly measures coronary artery motion by exciting the surrounding epicardial fat and sampling the signal with a k-space trajectory sensitized to various motion parameters. The present preliminary human study demonstrates that superior-inferior (SI) respiratory motion of the coronary arteries detected by the cardiac fat NAV highly correlates with SI diaphragmatic motion detected by the pencil-beam NAV. In addition, the cardiac fat navigator gating is slightly more effective than the diaphragmatic navigator gating in suppressing motion artifacts in free-breathing 3D coronary MR angiography (MRA).
منابع مشابه
Cardiac Fat Navigator for Real-Time Motion Gated 3D Coronary MRA
T. D. Nguyen, A. Nuval, Y. Wang University of Pittsburgh Medical Center, Pittsburgh, PA, United States SYNOPSIS Cardiac fat navigator detects coronary motion directly by exciting and sampling the epicardial fat that surrounds the proximal coronary arteries. The present study demonstrates that motion detected by the cardiac fat navigator at mid-diastole correlates with motion detected by the dia...
متن کاملHigh resolution, free-breathing coronary artery imaging with >99% respiratory efficiency: comparing beat to beat respiratory motion correction with navigator gating
Introduction: High-resolution coronary artery imaging is commonly gated to end-expiration using diaphragmatic navigator echoes, resulting in inherently low respiratory efficiency (RE) which is further exacerbated by respiratory drift. Recently, it was demonstrated that epicardial fat can be used as a marker of coronary artery position in a 3D beat-to-beat non-model based subject-specific respir...
متن کاملNavigator echoes in cardiac magnetic resonance.
Navigator echoes are frequently used in cardiac magnetic resonance to monitor respiratory motion and have proved particularly useful in coronary artery imaging techniques where they allow the acquisition of data over multiple reproducible breathholds and during free breathing. The large number of variables involved in their use, however, is such that an optimal method of application may yet hav...
متن کاملModel-free slice following using the cardiac fat navigator: enhanced gating efficiency for 3D SSFP coronary magnetic resonance angiography
INTRODUCTION Free-breathing coronary MRA (CMRA) typically uses a diaphragm navigator (NAV) for respiratory motion suppression, which is an indirect measure of the respiration-induced cardiac motion (1, 2). Slice tracking (3, 4) can be used to widen the acceptance window to improve navigator efficiency, but relies on a linear motion model to derive heart displacement. A linear correction factor ...
متن کاملReal-Time Navigator Approach to Motion Problems in Coronary MRA
This paper is a summary discourse on the real time navigator approach to suppressing motion effects in coronary magnetic resonance angiography. The concept of navigator approach, characteristics of coronary motion, design of navigator echoes for motion measurements, and navigator algorithms for motion effects suppression are reviewed and discussed. At the conclusion, an efficient and effective ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 50 2 شماره
صفحات -
تاریخ انتشار 2003