Comparative evaluation of BACTEC MGIT 960 with BACTEC 9000 MB and LJ for isolation of mycobacteria in The Gambia.

نویسندگان

  • Jacob Otu
  • Martin Antonio
  • Yin Bun Cheung
  • Simon Donkor
  • Bouke C De Jong
  • Tumani Corrah
  • Richard A Adegbola
چکیده

BACKGROUND The BACTEC MGIT 960 was evaluated and compared with BACTEC 9000 MB and Lowenstein-Jensen medium for recovery rate of mycobacteria, time to detection, and contamination rate. METHODOLOGY 147 sputum samples obtained from patients with suspicion of tuberculosis were processed and inoculated into BACTEC MGIT 960, BACTEC 9000 MB and Lowenstein-Jensen medium using standardized procedures. RESULTS BACTEC MGIT 960 detected 57.1%; BACTEC 9000 MB detected 57.8%; and LJ medium detected 43.5% specimens with Mycobacterium tuberculosis complex (MTBC). BACTEC MGIT 960 had the shortest mean number of days (10.3) to detection, followed by BACTEC 9000 MB (13.2) and LJ medium (26.1). Sign rank test showed all three methods had significant difference in days to detection (each P<0.0001). About 39% of detection by BACTEC MGIT 960 took place within the first week, compared to 27.0% and 0.0% by BACTEC 9000 MB and LJ medium respectively. The best yield was obtained with BACTEC 9000 MB, but when compared with the BACTEC MGIT 960, it was not statistically significant. Performances were the same when the combination of a liquid plus a LJ medium were measured (P=0.05). Contamination rates were significantly higher in BACTEC MGIT 960 (12%) than in BACTEC 9000 MB (7%) (P=0.041) and LJ (4%) medium (P=0.022). BACTEC 9000 MB and LJ medium have lower contamination rates (P=0.607). CONCLUSIONS BACTEC MGIT 960 had a shorter time to detection of MTBC than BACTEC 9000 MB and L J medium. Despite a higher contamination rate, its performance did not appear to be inferior.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the BACTEC MGIT 960 and BACTEC 460TB systems for detection of mycobacteria in clinical specimens.

The reliability of the Mycobacteria Growth Indicator Tube (MGIT) 960 system for rapid detection of mycobacteria in clinical specimens was evaluated and compared to the radiometric method (BACTEC 460TB) and to mycobacterial culture on Lowenstein-Jensen (LJ) medium. Clinical specimens (n = 590) were tested without selection. A total of 121 (20.5%) isolates of mycobacteria were recovered; 98 (81.0...

متن کامل

Comparison of recoveries of mycobacterium tuberculosis using the automated BACTEC MGIT 960 system, the BACTEC 460 TB system, and Löwenstein-Jensen medium.

Using two different liquid media and one conventional solid medium, a total of 57 mycobacterial isolates (Mycobacterium tuberculosis, n = 55; nontuberculous mycobacteria, n = 2) were recovered from 377 clinical specimens. The rates of recovery of M. tuberculosis were 96. 4% with the BACTEC MGIT 960 liquid medium, 92.7% with BACTEC 12B liquid medium, and 81.8% with the Löwenstein-Jensen (LJ) med...

متن کامل

Evaluation of BACTEC MGIT 960 and BACTEC 460TB systems for recovery of mycobacteria from clinical specimens of a university hospital with low incidence of tuberculosis.

Clinical samples obtained over a period of 8 months (n = 2,624) were processed in parallel with the BACTEC 460TB system, with the MGIT 960 system, and in Löwenstein-Jensen (LJ) medium, resulting in the recovery of 127 mycobacteria. Recovery rates in combinations of the BACTEC 460TB or MGIT 960 system with LJ were, respectively, 94.7 and 94.7% for Mycobacterium tuberculosis complex (n = 57) and ...

متن کامل

Filtration of cerebrospinal fluid improves isolation of mycobacteria.

Clinical diagnosis of tuberculous meningitis (TBM) is difficult due to the disease’s inconsistent clinical presentation. Furthermore, owing to the paucibacillary nature of cerebrospinal fluid (CSF), traditional techniques for detecting acid-fast bacilli have limitations. Hence, isolating mycobacteria from CSF by culture is a challenge. There is a dire need to improve, accelerate, and enhance is...

متن کامل

Rapid isolation of Mycobacteria--need of the hour in our settings.

BACKGROUND To compare Bactec MGIT 960 with LJ media in terms of time taken for the initial isolation of mycobacteria. METHODS A total of 100 AFB (acid fast bacillus) positive sputum samples were processed and inoculated in both the Lowenstein Jensen (LJ) media and mycobacterium growth indicator tube (MGIT) tubes. RESULTS Of the 100 samples, positive growth was obtained from all the samples ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of infection in developing countries

دوره 2 3  شماره 

صفحات  -

تاریخ انتشار 2008