Investigation of Indoor Air Quality in Houses of Macedonia
نویسندگان
چکیده
People who live in buildings are exposed to harmful effects of indoor air pollution for many years. Therefore, our research is aimed to investigate the indoor air quality in family houses. The measurements of indoor air temperature, relative humidity, total volatile organic compounds (TVOC), particulate matters (PM) and sound pressure level were carried out in 25 houses in several cities of the Republic of Macedonia. Mean values of indoor air temperature and relative humidity ranged from 18.9 °C to 25.6 °C and from 34.1% to 68.0%, respectively. With regard to TVOC, it can be stated that excessive occurrence was recorded. Mean values ranged from 50 μg/m³ to 2610 μg/m³. Recommended value (200 μg/m³) for human exposure to TVOC was exceeded in 32% of houses. Mean concentrations of PM2.5 (particular matter with diameter less than 2.5 μm) and PM10 (diameter less than 10 μm) are determined to be from 16.80 μg/m³ to 30.70 μg/m³ and from 38.30 μg/m³ to 74.60 μg/m³ individually. Mean values of sound pressure level ranged from 29.8 dB(A) to 50.6 dB(A). Dependence between characteristics of buildings (Year of construction, Year of renovation, Smoke and Heating system) and data from measurements (Temperature, Relative humidity, TVOC, PM2.5 and PM10) were analyzed using R software. Van der Waerden test shows dependence of Smoke on TVOC and PM2.5. Permutational multivariate analysis of variance shows the effect of interaction of Renovation and Smoke.
منابع مشابه
Investigation on mycoflora of poultry breeding houses’ air and studying the efficacy of spraying and fumigation on inactivating the airspora
Background: A common concern of the poultry industry is the presence of fungal pathogens in the birds’ environment, which may constitute a considerable health hazard to the birds, farmers, and those living in proximity of the farm. OBJECTIVES: The aims of this study were to assess the mycoflora in the indoor and outdoor environments of poultry breeding houses and studying the efficacy of disinf...
متن کاملInvestigation of indoor air pollution by chlorpyrifos: Determination of chlorpyrifos in indoor air and 3,5,6-trichloro-2-pyridinol in residents' urine as an exposure index.
OBJECTS We carried out an investigation to clarify the real state of indoor air pollution by chlorpyrifos (termiticide) and exposure to chlorpyrifos of residents by measuring its urinary metabolite 3,5,6-trichloro-2-pyridinol (TCP) as an exposure index, such as biological monitoring. METHODS The investigation was conducted in 43 individual houses with termiticide application (whether the term...
متن کاملIndoor air quality monitoring in urban areas using Smart Sensing Technology
Recently, indoor air quality has attracted the attention of policymakers and researchers as a critical issue like that of external air pollution. Indoor air quality is more important as people spend time longer indoors than outdoors. Indoor environments are closed compared to external environments providing less opportunity for the pollutants to dilute. The emissions contain many substances tha...
متن کاملAn Assessment of Indoor Air Quality and Thermal Comfort in Educational Spaces (Case Study: Girls' High Schools in Arak, Iran)
As students spend one-third of their time at school, their health, comfort, and productivity are mostly influenced by thermal condition and indoor air quality of classrooms. Regarding that manual window-opening is a common way for providing fresh air in classes and students aren't allowed to change their uniform, position or control the windows during the lesson hours, providing thermal comf...
متن کاملIndoor Radon Measurement in Dwellings of Khorramabad City, Iran
Introduction: Exposure to indoor radon increases the risk of lung cancer. This study examined the level of indoor radon in dwellings of Khorramabad city, by using passive alpha-track detector (CR-39) during winter of 2016. Materials and Methods: In the present study, we detected the concentration of indoor radon in 56 dwellings. A passive sampling instrument (alpha-track detector with CR-39 pol...
متن کامل