The thoracodorsal artery perforator flap: clinical experience and anatomic study with emphasis on harvest techniques.
نویسندگان
چکیده
The thoracodorsal artery perforator flap is a relatively new flap that has yet to find its niche in reconstructive surgery. At the authors' institution it has been used for limb salvage, head and neck reconstruction, and trunk reconstruction in cases related to trauma, burns, and malignancy. The authors have found the flap to be advantageous for cranial base reconstruction and for resurfacing the face and oral cavity. The flap has been used successfully for reconstruction of traumatic upper and lower extremity defects, and it can be used as a pedicled flap or as a free tissue transfer. The perforating branches of the thoracodorsal artery offer a robust blood supply to a skin-soft-tissue paddle of 10 to 12 cm x 25 cm, overlying the latissimus dorsi muscle. The average pedicle length is 20 cm (range, 16 to 23 cm), which allows for a safe anastomosis outside the zone of injury in traumatized extremities; the flap can be made sensate by neurorrhaphy with sensory branches of the intercostal nerves. Vascularized bone can be transferred with this flap by taking advantage of the inherent vascular anatomy of the subscapular artery. A total of 30 pedicled and free flap transfers were performed at the authors' institution with an overall complication rate of 23 percent and an overall flap survival rate of 97 percent. Major complications, such as vascular thrombosis, return to the operating room, fistula formation, recurrence of tumor, and flap loss, occurred in 17 percent of the patients. Despite these drawbacks, the authors have found the thoracodorsal artery perforator flap to be a safe and extremely versatile flap that offers significant advantages in acute and delayed reconstruction cases.
منابع مشابه
Bilateral Breast Reconstruction with Extended Thoracodorsal Artery Perforator Propeller Flaps and Implants
We present our experience of bilateral total breast reconstruction using a double-sided extended thoracodorsal artery perforator propeller flap in a case series of 10 patients. Reconstruction was successfully achieved in all cases with few complications. The median time for surgery was 275 minutes (200-330), and the average implant size used was 350 cm(3) (195-650). We demonstrate how the exten...
متن کاملPedicled Thoracodorsal Artery Perforator Flap in Breast Reconstruction: Clinical Experience
BACKGROUND The thoracodorsal artery perforator (TDAP) flap has been described for reconstruction of the head and neck, trunk and extremities. Yet, its use as a pedicled flap in breast reconstruction has not gained wide popularity and has not been widely documented, especially not for complete breast reconstruction or in combination with expanders or permanent implants. The authors present their...
متن کاملThe Anterior Interosseus Artery Perforator Flap: Anatomical Dissections and Clinical Study
BACKGROUND Reconstruction of upper extremity deformities continues to be a challenge to the reconstructive surgeon. Various loco regional, distant and free flaps are available for reconstruction. However, each has its own set of advantages and disadvantages. Of the commonly performed local flaps, radial artery forearm flap, and the posterior interosseus artery flap stand out prominently. Rec...
متن کاملPractical Considerations for Perforator Flap Thinning Procedures Revisited
BACKGROUND A thin perforator flap is one of the best methods for covering defects. This study aimed to revisit and further test the rapidly advancing field of flap thinning techniques. METHODS We performed two cadaveric studies to test the known flap thinning methods, and then applied these methods to a clinical series. In the first study, five cadavers were used to observe the anatomical rel...
متن کاملPorcine Model for Gluteal Artery Perforator Flap: Anatomy and Technique
1 BACKGROUND Although flap anatomy is well studied on cadavers and microsurgical techniques are well practiced on rats, still there are few training models for learning the techniques of perforator flap harvesting. The cadaver has no bloodstream, so accuracy of dissection cannot be evaluated and flap viability cannot be verified. Training on humans carries a high risk of flap damage. A living m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Plastic and reconstructive surgery
دوره 114 1 شماره
صفحات -
تاریخ انتشار 2004